72
Firmware version 1.10 - Document version 1.06 - eng
LTDVE1CH-40F | INSTRUCTIONS MANUAL
Figure 34: main window after the MCU firmware file has been loaded
At this point the PC application is ready to connect to the controller and transfer all the new firmware
data. Now the controller must be switched off, if already powered, and then powered up with the INIT
button held pressed for just a second. In this way the controller will enter a special state when, for
ten seconds, will wait for new firmware data from the serial RS485 interface.
The firmware update sequence is then started by pressing the
Update
button. The PC application
connects to the controller and starts the data transfer and programming. The progress bar in the
middle of the main window keeps updating to show the advancement of the process. The text box
at the bottom of the main window is updated with more information regarding the updating process.
The first data transferred to the controller is the MCU firmware (see image in