Figure 14: the Setup pulse generators web page
Each pulse generator can be set independently. Each pulse generator is triggered by a selectable
source and can have a different pulse delay, pulse width and hold off interval.
•
Source
selects the trigger for the generator. It can be chosen between
Off
(default),
Input
TR
,
Oscillator
,
Software SW1
and
Software SW2
. When set to
Off
the generator is
disabled. When set to
Oscillator
the internal free running oscillator is used as the trigger
•
Edge
selects the triggering edge for the generator. It can be chosen between
Rising
(default),
Falling
and
Both
. With the latter selection the generator is triggered by both the
rising and falling edges
•
Pulse delay
is the delay of the generated pulse with respect to the triggering source. The
pulse delay may range from 0 µs to 1,023,000 µs with variable resolution
•
Pulse width
is the time duration of the generated pulse. The pulse width may range from 1
µs to 1,023,000 µs with variable resolution
•
Holdoff time
is the minimum time, after a pulse has been generated, that the relevant
generator waits before possibly producing a new pulse. The hold off interval may range from
0 µs to 1,023,000 µs with variable resolution
Settings
Pulse delay
,
Pulse width
and
Holdoff time
are expressed in μs.
14.3.4. Setup light outputs