LTDVE1CH-40F | INSTRUCTIONS MANUAL
light output LD. The
Setup light outputs
Figure 15: the Setup light outputs web page
The fields under
Converter settings
collect all the settings related to the DC/DC converter. Basically,
the DC/DC converter output voltage can be manually set to a specified value or can be automatically
detected by the controller itself.
•
Converter mode
selects the operating mode for the DC/DC converter. It can be chosen
between
Fixed voltage
(default) and
Autodetect voltage.
When set to
Autodetect voltage
the controller detects the lowest converter output voltage sufficient to drive the programmed
current into the light. By selecting the lowest converter output voltage, the heat generated by
the controller is minimized
•
Converter maximum voltage
is the maximum voltage the DC/DC converter is ever allowed
to produce. This register defines the actual output voltage when the DC/DC converter
operates in fixed voltage mode. Conversely, when the DC/DC converter is set to
automatically detect the output voltage, this register will be overwritten with the final output
voltage value reached on the DC/DC converter
•
Converter preset voltage
is the actual output voltage setting for the DC/DC converter
The light output can have a specific activation source, output current and independent maximum
turn-on and minimum turn-off parameters. Moreover, the protection against excessive turn-on time
and protection against insufficient turn-off time can be enabled or disabled for the light output.
•
Source
selects the activation source for the light output. It can be chosen between
Off
(default),
Generator GN1
,
Generator GN2
,
Input TR
and
Continuous
. When set to
Off
the