54
Firmware version 1.10 - Document version 1.06 - eng
LTDVE1CH-40F | INSTRUCTIONS MANUAL
Figure 13: the Setup synch inputs web page
The synchronization input has a programmable polarity control. The available selections are:
•
Normal: polarity is active high (default value)
•
Inverted: polarity is active low
The synchronization input has a digital filter. The filter can be enabled or disabled. If enabled, it can
be set to one of six predefined time constants. The available selections are:
•
Off: the filter is disabled (pass through) (default value)
•
10 µs: the filter is enabled with a 10 µs time constant
•
20 µs: the filter is enabled with a 20 µs time constant
•
50 µs: the filter is enabled with a 50 µs time constant
•
100 µs: the filter is enabled with a 100 µs time constant
•
200 µs: the filter is enabled with a 200 µs time constant
•
500 µs: the filter is enabled with a 500 µs time constant
14.3.3. Setup pulse generators
This page allows to inspect and change all the settings related to the pulse generators. The
Setup
pulse generators
Figure 14: the Setup pulse generators web page