Page:
36
Code:
000088BG
Chapter:
7
This document is the property of the Manufacturer and/or its
Agent and must not to be tampered with or changed, reproduced or provided to others without written consent.
DIE INSERTION WITH STANDARD QUICK CHANGE TOOL
1. Verify that the machine is completely open with the
vernier dial
21
set to zero.
2. Chose the new set of dies and then insert the standard quick change
tool taking care that the 8 pins tally in the front holes of the dies
06
.
3.
When the dies are hooked through the magnets, rotate the standard
quick change tool lightly counterclockwise and draw the whole out
of the shells
12
.
4.
Put the standard quick change tool between the dieholders,
ensuring that the pins on the dies are aligned with the holes on
the dieholder.
We are now positioned for the quick die insertion.
5. Press button
E05
make the piston move slowly forward till the
end of the stroke so as to have the dieholder close, automatically
the dies will hook.
6.
Draw the standard quick change tool out of the holes of the dies,
the replacement of the dies is now completed
N.B. This device, being without a centering guide,
requires more attention by operator that must make
sure that quick change is correctly positioned during
insertion.
WARNING:
in the phases 4 make sure to align the pins on the dies
and the holes on the dieholders, then press the short
intermitience “close” button to prevent damage to the
equipment or the operator.
N.B. Start the machine before beginning the quick
change die process.
“N”
“N”
“N”
“N”
“N”
“N”
“N”
“N”
“N”
“N”