Seite:
78
Kap.:
10
Die vorliegende Unterlage ist Eigentum des Herstellers u/o seines V
ertreters und darf auf keinen Fall vervielfältigt, als auch nicht an Dritte ohne Einverständnis weitergegeben werden.
Kodex:
001032AD
Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
DD51-E
Direct drive electronic position indicators
The available parameters and their descriptions are listed in the
following table.
Parameter
Description
Available
options
Standard
value
dir
Rotation
direction
--o
clockwise
o--
counterclockwise
--o
OrG
Absolute
reference
value
-9999
;
9999
The parameter value depends on the
unit of measure selected.
0
OFFS
Compensation
values
(Offset)
-9999
;
9999
The system allows you to store up to
10 compensation values:
OFS 0
...
OFS 9
The parameter value depends on the
unit of measure selected.
0
StEP
Reading after
one revolution
0.01
;
100.00
001.00
rES
Resolution
mm:
1
;
0.1
;
0.01
inches:
0.001
;
0.01
;
0.1
;
1
degrees:
0.01
;
0.1
;
1
mm:
0.1
inches:
0.01
degrees:
1
diSP
Display
orientation
0°
:
display right
180°
: display reverse
0°
SPEEd
Reading max
speed [rpm]
300
;
600
;
1000
600
_ _ 0 _ _
Key function
ArCLr
: switching from
ABS
to
REL
the counter is set to zero.
Ar
: switching from
ABS
to
REL
the
counter is not set to zero.
OFF
: the key is not assigned to
any function in the operating mode
ArCLr
_ _ _ _ 0
Key function
ALL
: selectable units of measure:
mm, inch, D
nodEG
: selectable units of measure:
mm, inch
OFF
: the key does not allow the unit
of measure conversion
ALL
0 _ 0 _ _
Key
combination
function
+
L_OrG
: the key combination sets
the absolute value to the sum of
OrG
+
OFFS
parameters
OFF
: lthe key combination is not
assigned to any function in the
operating mode
L_OrG
0 _ _ _ 0
Key
combination
function
+
The key combination activates the
direct programming of the following
parameters:
P_OrG
: parameter
OrG
P_StP
: parameter
StEP
P_OFS
: parameter
OFFS
OFF
: lthe key combination is not
assigned to any function in the
operating mode
P_OrG
PASS
Password
ON
: the system requires the password
22011 to enter the programming mode
OFF
: the system does not require a
password to enter the programming
mode
OFF
Parameter
Description
Available
options
Standard
value
rESEt
Setting of
Parameters
to standard
values
YES
: the parameters are set to the
standard values
NO
: the parameters maintain the
values set by the user
NO
rE
Software
version
The software version is shown on the
display.
9. Problem solving
Message on
the display
Description
Action
-----
Exceeding the reading scale
(-19999;99999)
The value cannot
be shown on the display.
The system continues to
measure displacements; the
value will be shown on the
display again if re-included in
the reading scale.
S_Err
The shaft speed has exceeded the
max system speed.
Press the key to go back to the
value reading and re-set the
absolute reference.
Flashing
battery symbol
Low Battery
Replace the battery
(see paragraph 7.5).