Page:
41
Code:
000090AG
Chapter:
This document is the property of the Manufacturer and/or its
Agent and must not to be tampered with or changed, reproduced or provided to others without written consent.
8
Routine maintenance
DESCRIPTION OF MAINTENANCE AND CHECKS
-
Each day
clean the working environment and
workplace, technical
and accident prevention information plates, control panels and the
whole machine in general (e.g. an oily or dirty handle may give rise to
a dangerous situation).
Especially, use a jet of compressed air to remove dust deposits, water,
or dirt from the shells
12
and dies
06
.
-
Each year
check and tighten all the bolts on the machine, applying
adequate tightening torques.
Also check that the cable die on the electrical equipment is tight, as
well as the integrity of the power supply cable and protective sheaths.
-
Each day
carry out a visual check of the safety systems and check
their activation.
At the end of each shift
check that the main switch
IG
is working as well as the nearby switch installed by the Client.
-
Each month
check the oil level in the hydraulic unit
01
.
Top up if necessary (see Table: Lubricants and symbols).
the hydraulic oil must be changed
every 2 years
or more frequently
depending on how frequently it is used – check its viscosity. Change
the gaskets on the hydraulic cylinder
04
and high pressure joined hoses
every 6 years
irrespective of leaks or cracks.
-
Each year
change or clean the
submerged filters
10
. at the same time
check the state and noise levels of the pumps
09
. Get them changed
if pressure drops or excessive noise occur.
-
Each year
check the setting value for the pressure reducing valves
as indicated in the hydraulic diagram. at the same time check the
efficiency of the pressure gauges that provide the pressure readings.
-
Each day
check that there is no seepage from piping and hosefittings.
Tighten the nuts and if the seepage persists change the hosefitting,
hose, or gasket (if fitted).
-
Each month
check that when the oil is heated up it does not exceed
the recommended maximum operating temperature of 50°C.
-
Every 6 months
, lubricate moving parts. For the type of grease re
-
commended see table: lubricants and symbols
- When the machine has been working
for about six years
check and
fully service the machine.
For this task contact the Manufacturer or their Agent.
24 h
24 h
24 h
2.000 h
2.000 h
200 h
12.000 h
2.000 h
200 h
4.000 h
12.000 h
1.200 h
SYMBOLS AND FREQUENCY