Page:
33
Code:
000089DG
Chapter:
7
This document is the property of the Manufacturer and/or its
Agent and must not to be tampered with or changed, reproduced or provided to others without written consent.
N.B. after turning the master switch, wait a few secon-
ds while the power supply is loading
OPERATING PROCEDURE
1.
Decide the final crimp diameter required (the final crimp diameter
is supplied by the producers of the fittings; follow their instructions)
and insert the proper set of dies (see chapter “ISTRUMENTATION”)
2.
Insert the hose with the fittings and bush, already prefitted, between
the dies.
3. turn the “Power switch” and press the “start” button
E01
4. Bear in mind that every millimeter of advancement of the knurled
handwheel on the graduated rod corresponds to ±1 millimetre of
variation on the die closing. When the knurled handwheel is in
position 0 on the graduated rod, the final diameter corresponds to
the nominal diameter of the die which is printed on it. Each notch
of the knurled handwheel corresponds to ±0.1 mm on the diameter.
Example: in order to obtain a final diameter of 12 mm, use a die with
size 10. Considering that the difference between the two diameters
is 2 mm, the knurled handwheel should be turned twice completely,
so as to be positioned at no. 2 of the graduated rod.
5.
Regulate the crimping time by means of the potentiometer E12 (it
can be set between 0 and 10 sec. and it starts once the crimping
diameter is reached).
Note: If E12 is positioned on minus, the counting of
the crimping time is not performed.
6. regulate the reopening of the machine by means of the potentio-
meter E11
.
Note: If E11 is positioned on minus, the regulation is
disabled.
7.
Once the crimping diameter, the crimping time and the reopening
of the machine have been adjusted, press the E05 “Closing” button
and wait for the piston stroke to automatically stop and the lED
E06 to light on: this indicates that the quote has been reached (if
the potentiometer E12 is set on a value between – “and” +, the LED
E06 will blink for the same time set).
8. Press the “Open” button
E04
to make the piston back up, and
remove the crymped hose.
Note: If not used, the switching off is automatic after
3 minutes
IG
E11
E12
E06