Operation
72
NOTE:
To make a program run automatically when the Compute Box is powered
on just leave the program running while you power the Compute Box off.
To start a new program, click on the
New
button.
•
To add a new row, click on the
Add new conditions and commands
.
•
To delete a row, click on the
icon.
•
To move the row up or down click on the
icons.
NOTE:
Conditions and commands are executed from the top to the bottom.
Same commands at the bottom can override the ones at the top.
•
To duplicate a row click on the
icon.
•
To disable a row (not to be executed) uncheck the checkbox
next to the row number.
The rows must have at least one condition and at least one command to be executed.
Conditions
Conditions are the input fields marked by blue.
There are two types of conditions:
•
Digital Input type - like DI4=1
•
Device specific value type - like HEX Fx > 10N
These types of conditions can be combined with AND or OR logic to form a more complex condition:
If
( DI4=1 )
OR
(HEX Fx > 10 N
AND
HEX Fx < 20N )
Condition is true if Fx is between 10N and 20N or robot has signaled high in Digital Input 4.
Digital inputs (DI1-DI8) can have the following three states: (click to cycle through the states)
•
-
Don’t care (this bit is masked and will give true result for the bit)
•
- give logic true if Input bit is low
•
-give logic true if Input bit is high
Содержание Gecko Gripper
Страница 1: ...USER MANUAL FOR NACHI ROBOTS ORIGINAL INSTRUCTION EN v1 05...
Страница 12: ...Operationmode s 12 Mode I OnRobot EtherNet IP...
Страница 26: ...Installation 26...
Страница 47: ...Operation 47...
Страница 48: ...Operation 48 Mode II OnRobot WebLogic...
Страница 64: ...Installation 64...
Страница 106: ...Additional Software Options 106 HEX E H QC RG2 6 T Oassemblyid 150 T Odata size 40 bytes T Oparameters...
Страница 113: ...Additional Software Options 113 RG2 6 VG10 VGC10 T Oassemblyid 156 T Odata size 64 bytes T Oparameters...
Страница 115: ...Additional Software Options 115 O Tassemblyid 157 O Tdata size 64 bytes O Tparameters...
Страница 117: ...Additional Software Options 117 RG2 6 Gecko T Oassemblyid 158 T Odata size 64 bytes T Oparameters...
Страница 123: ...Additional Software Options 123...
Страница 135: ...Hardware Specification 135 RG2 FT GrippingSpeedGraph GripperWorkingRange The dimensionsare in millimeters...
Страница 139: ...Hardware Specification 139 RG2 GrippingSpeedGraph RG2 Work Range...
Страница 142: ...Hardware Specification 142 RG6 GrippingSpeedGraph RG6 Work Range...
Страница 162: ...Hardware Specification 162 9 2 Mechanical Drawings 9 2 1 Adapter plate s...
Страница 163: ...Hardware Specification 163 Adapter I...
Страница 164: ...Hardware Specification 164 Adapter J...
Страница 170: ...Hardware Specification 170 Gecko All dimensionsare in mm and inches...
Страница 171: ...Hardware Specification 171 RG2 FT All dimensionsare in mm and inches...
Страница 172: ...Hardware Specification 172 RG2 All dimensionsare in mm and inches...
Страница 173: ...Hardware Specification 173 RG6 All dimensionsare in mm and inches...
Страница 174: ...Hardware Specification 174 VG10 All dimensionsare in mm and inches...
Страница 175: ...Hardware Specification 175 All dimensionsare in mm and inches...
Страница 176: ...Hardware Specification 176 VGC10 All dimensionsare in mm and inches...
Страница 177: ...Hardware Specification 177 All dimensionsare in mm and inches...
Страница 178: ...Hardware Specification 178 Quick Changer Tool side All dimensionsare in mm and inches...
Страница 185: ...Certifications 185 12 Certifications...
Страница 186: ...Certifications 186...
Страница 187: ...Certifications 187...
Страница 188: ...Certifications 188...
Страница 189: ...Certifications 189...
Страница 190: ...Certifications 190...