3-15
ZUV
User’s Manual
Sect
ion 3
SETUP
Section 3
Setting/Executing Power Tuning
Setting [POWER TUNING] to [ON] lowers the actual irradiation intensity when compared
with the state of the [OFF] setting even if the same irradiation power is set.
●
Flow chart of power tuning
■
Setting power tuning to ON
Set power tuning.
LOCK mode-[TOOL]-[POWER TUNING]-[ON/OFF]
Setting value
Description
OFF
• Setting/execution of the reference value for power tuning are disabled.
• The irradiation intensity at the same irradiation power is higher than that
when power tuning is set to ON. (default value)
• When OFF is selected, the power tuning reference value that was set
when power tuning was set to ON is cleared.
ON
• Setting/execution of the reference value for power tuning are enabled.
• The irradiation intensity at the same irradiation power is lower than that
when power tuning is set to OFF.
Time
Execute
Execute
Execute
Output (irradiation) light intensity
Registering a reference
UV irradiation power
Performing tuning
periodically
Set the reference
value.
Set power tuning to ON.
Correct to a
reference value.
Содержание ZUV Series
Страница 1: ...Smart Curing System User s Manual Cat No Z281 E1 02 ZUV Series Mega Power Type...
Страница 18: ...16 ZUV User s manual CONTENTS Introduction CONTENTS MEMO...
Страница 44: ...2 18 Section 2 ZUV BASIC OPERATION ZUV User s Manual Section 2 Operating Modes MEMO...
Страница 68: ...3 24 Section 3 SETUP ZUV User s Manual Section 3 Setting the System Environment MEMO...
Страница 120: ...5 12 Section 5 APPENDIX ZUV User s Manual Section 5 Requirements from Regulations and Standards...
Страница 123: ...5 15 ZUV User s Manual Section 5 APPENDIX Section 5 INDEX MEMO...
Страница 125: ......