4-32
Section 4
CONNECTING TO EXTERNAL DEVICES
ZUV
User’s Manual
Section 4
Connection by USB/RS-232C
SYSSET command
The system data is set.
(1)
Parameter description
The following parameters can be obtained by the SYSSET command:
SYSSET <Parameter No.> <Write data>
OK
Parameter
No.
Details
Write Data (Setting Range/Output Range)
0
READY mode display data No.
0: Irradiation Conditions List Display
1: Irradiation Power Adjustment Display
2: Channel Specific Detail Display
3: Cumulative Energy List Display
1
LANGUAGE
0: JAPANESE
1: ENGLISH
2
Buzzer volume
0: OFF
1: ON
3
ECO display
0: OFF
1: ON
4
Menu color
0: MARINE BLUE
1: GRASS GREEN
2: ORANGE PEEL
3: STYLISH GRAY
4: SALMON PINK
5: NIGHTMARE
5
Irradiation control
0: ALL CH
1: INDIVIDUALLY
6
Analog input voltage
0: 1 to 5V
1: 0 to 1V
7
TERMINAL IN
0: CONTACT
1: SWITCH
8
RS-232C baud rate
0: 9600
1: 19200
2: 38400
3: 57600
4: 115200
9
RS-232C bit length
0: 8BIT
1: 7BIT
10
RS-232C parity
0: NONE
1: ODD
2: EVEN
11
RS-232C stop bit
0: 1BIT
1: 2BIT
Command
Delimiter
Delimiter
Response
Delimiter
Delimiter
Содержание ZUV Series
Страница 1: ...Smart Curing System User s Manual Cat No Z281 E1 02 ZUV Series Mega Power Type...
Страница 18: ...16 ZUV User s manual CONTENTS Introduction CONTENTS MEMO...
Страница 44: ...2 18 Section 2 ZUV BASIC OPERATION ZUV User s Manual Section 2 Operating Modes MEMO...
Страница 68: ...3 24 Section 3 SETUP ZUV User s Manual Section 3 Setting the System Environment MEMO...
Страница 120: ...5 12 Section 5 APPENDIX ZUV User s Manual Section 5 Requirements from Regulations and Standards...
Страница 123: ...5 15 ZUV User s Manual Section 5 APPENDIX Section 5 INDEX MEMO...
Страница 125: ......