234
Note: 1. Not initialized by constant initialization.
2. Upper limit of setting range and factory setting are doubled for 400 V
Class.
3. Depends on Inverter capacity. Refer to the next page.
4. Depends on Inverter capacity. Refer to page 91.
5. Factory setting of the model with JVOP-147 Digital Operator (with-
out potentiometer) is 0. Setting can be set to 1 by constant initializa-
tion.
6. When control mode selection (n002) is changed, factory setting corre-
sponds to the control mode. Refer to the next page.
7. Do not select 3 to 100 as they are reserved for future use.
* 1. Values are doubled for 400 V Class.
175
01AF
Reducing Carrier Frequency
Selection at Low Speed
0, 1
-
0
No
92
176
01B0
Constant Copy Function
Selection
rdy, rEd, CPy,
vFy, vA, Sno
-
rdy
No
162
177
01B1
Constant Read Selection
Prohibit
0, 1
-
0
No
163
178
01B2
Fault History
Stores, dis-
plays most
recent 4
alarms
Setting
disabled
-
No
47
179
01B3
Software Version No.
Displays
lower-place 4
digits of soft-
ware No.
Setting
disabled
-
No
-
No.
Name
V/f Control
Mode
(n002 = 0)
Vector Con-
trol Mode
(n002 = 1)
n014
Mid. Output Frequency
1.3 Hz
3.0 Hz
n015
Mid. Output Frequency Voltage
12.0 V
*1
11.0 V
*1
n016
Min. Output Frequency
1.3 Hz
1.0 Hz
n017
Min. Output Frequency Voltage
12.0 V
*1
4.3 V
*1
n104
Torque Compensation Time Constant
0.3 s
0.2 s
n111
Slip Compensation Gain
0.0
1.0
n112
Slip Compensation Gain Time Constant
2.0 s
0.2 s
No. Register
No. for
Trans-
mission
Name
Setting Range Setting Unit
Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page