9 Specifications
211
Standard Specifications (400 V Class)
Voltage Class
400 V 3-phase
Model CIMR-V7TZ
3-phase
40P4-05
40P7-05
41P5-05
42P2-05
43P0-05
44P0-05
Max. Applicable Motor Output kW
*1
0.55
1.1
1.5
2.2
3.0
4.0
Inverter Capacity (kVA)
1.4
2.6
3.7
4.2
5.5
7.0
Rated Output Current (A)
1.8
3.4
4.8
5.5
7.2
9.2
Max. Output Voltage (V)
3-phase, 380 to 460 V (proportional to input voltage)
Max. Output
Frequency (Hz)
400 Hz (Programmable)
Rated Input Voltage and
Frequency
3-phase, 380 to 460 V, 50/60 Hz
Allowable Voltage
Fluctuation
−
15 to +10%
Allowable Frequency
Fluctuation
±
5%
Control Method
Sine wave PWM (V/f control/vector control selectable)
Frequency Control Range
0.1 to 400 Hz
Frequency Accuracy
(Temperature Change)
Digital reference:
±
0.01 %,
−
10 to 50
°
C (14 to 122
°
F)
Analog reference:
±
0.5 %, 25
±
10
°
C (59 to 95
°
F)
Frequency Setting Resolu-
tion
Digital reference:
0.01 Hz (less than 100 Hz)/0.1 Hz (100 Hz or more)
Analog reference: 1/1000 of max. output frequency
Output Frequency
Resolution
0.01 Hz
Overload Capacity
150% rated output current for one minute
Frequency Reference Sig-
nal
0 to 10 VDC (20 k
Ω
), 4 to 20 mA (250
Ω
), 0 to 20 mA (250
Ω
) pulse
train input, frequency setting potentiometer (Selectable)
Acceleration/Deceleration
Time
0.00 to 6000 s
(Acceleration/deceleration time are independently programmed.)
Braking Torque
Short-term average deceleration torque
*2
0.75 kW: 100% or more
1.5 kW (2 HP): 50% or more
2.2 kW (3 HP) or more: 20% or more
Continuous regenerative torque: Approx. 20% (150% with optional
braking resistor, braking transistor built-in)
V/f Characteristics
Possible to program any V/f pattern
Output Charact
eris
tics
Po
we
r S
u
pp
ly
Control C
harac
teristics