6 Programming Features
107
* 1. For more information on how to select the sequence polarity, refer to page
218.
* 2. Numbers 1 to 7 are displayed for
to indicate the terminal numbers S1 to
S7.
Factory Settings
Terminal Functions for 3-wire Sequence Selection
When 0 is set for terminal S3 (n052), terminal S1 is the Run Command,
terminal S2 is the Stop Command, and terminal S3 is the FWD/REV
Run Command.
33
no function
-
34
UP/DOWNcommands
setting enabled only for n056
108
35
Do not set.
-
36
UP2 / DOWN2 commands
setting enabled only for n056
110
37
FWD/REV Run 2 Command
(2-wire sequence 2)
123
No.
Terminal
Factory Setting
Function
n050
S1
1
Forward Run Command
(2-wire sequence)
n051
S2
2
Reverse Run Command
(2-wire sequence)
n052
S3
3
External fault (NO contact input)
n053
S4
5
Fault Reset
n054
S5
6
Multi-step speed reference 1
n055
S6
7
Multi-step speed reference 2
n056
S7
10
Jog Command
Setting
Name
Description
Ref.
page
Run Command
(Run when Closed)
Stop Command
(Stop when Open)
FWD/REV Run Selection
FWD Run When Open
REV Run When Closed
RUN SW
(NO Contact)
STOP SW
(NC Contact)
V7TZ