Appendices
R-6
V440-F C-Mount Code Reader User Manual
What is the readable
installation distance?
That of V440-F depends on the cell size (bar width) of a target code too.
The reference values are described on page A-5 to A-6, refer to them.
The read range is described, which was possible to read with typical cell size examples for the design readable focal
distance per format.
* For barcode, a half size of the bar width for readable values of 2D code cell size is a guide.
How to shorten the read
time?
Please consider below.
• Construct appropriate optical conditions like an image is in focus or having sufficient contrast.
Mount distance, Mount angle, Exposure time)
• Limit symbol types for the read target.
• Enable the optimization. (Graph icon on the setup screen)
• Perform the Window of Interest.
What parameters need to
be adjusted when a
symbol is unable to
read?
Adjust the following parameters.
What is the number of
the maximum characters
for Match String
Database?
It is 3,000 characters.
It is divided by the number of registrations, so it varies depending on the number of registrations.
When the number of registrations is one, it can register up to 3,000 characters.
When the number of registrations is ten, each registration can register up to 300 characters.
Related Q&A:
What is the number of the maximum readable characters?
How to change Match
String externally?
Use <K231> command.
Command format: <K231, index, master symbol data>
Example:
When setting
ABC
to the first Match String Database:
<K231, 1, ABC>
How to enable the
External Trigger rather
than Continuous Read?
Set the Trigger Mode except for
Continuous Read
. Refer to the following instruction.
Select Gear icon -
Advanced - Read Cycle
-
Trigger - Mode
-
External Edge or Serial Data and Edge
.
How can I confirm the
OK/NG Read result over
EtherNet/IP?
The method differs according to the selected input assembly.
• When using a Small (100) assembly;
First determine whether the Output String (DECODE DATA STRING) is
NOREAD
(default).
• When using a Big (101) assembly;
There is a way to verify the
External Output Status
OUTPUT bit.
Please note that the
External Output Status
is dependent on the Output condition setting for the Parallel I/O OUTPUT
signal. The default setting is ON when there is a Read Fail.
• When an assembly after MXL/SLC (102) is selected;
You can verify the
Read Cycle Pass
,
Read Cycle Fail
bit status in
Device Status
. The
Read Cycle Pass
,
Read Cycle
Fail
bit is OFF during a READ cycle and is updated when
Data Is Ready
is ON.
Symbol state
Adjustment
An image is dark.
Adjust
Exposure
or
Gain
to bright the image.
Out of focus.
Adjust
Focus
to make the symbol in focus.
A cell size is small.
Change the mount distance or use a high pixel density and narrow
field of view type.
Noisy background
Remove noise with the Morphological Preprocessing. When 5 M
type is used, adjust the color filter.
The read time takes much
time.
Set
Timeout
longer.
The lighting is reflected.
Tilt the lighting by approx. 15 degrees to reduce the reflection. Or,
try to use the optional Polarizer (V430-AF12) and the Diffuser
(V430-AF11).
Содержание V440-F
Страница 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Страница 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Страница 37: ...2 Quick Start 2 6 V440 F C Mount Code Reader User Manual V440 F Lens Selection Based on Focal Length...
Страница 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Страница 151: ...6 Application Settings 6 4 V440 F C Mount Code Reader User Manual 6 3 New New opens a new WebLink session...
Страница 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Страница 224: ...A 3 Appendices V440 F C Mount Code Reader User Manual A V440 F Cable and Accessory Specifications...
Страница 225: ...Appendices A 4 V440 F C Mount Code Reader User Manual V440 F Cable and Accessory Specifications continued...
Страница 239: ...Appendices A 18 V440 F C Mount Code Reader User Manual M12 to RS 232 Breakout 1 Meter or 3 Meters V430 WR 1M V430 WR 3M...
Страница 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Страница 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Страница 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Страница 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Страница 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Страница 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Страница 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Страница 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Страница 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Страница 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...