M-7
Appendices
V440-F C-Mount Code Reader User Manual
M-
5 Master D
atab
ase
M
M-
5-1 Ma
ster
Symbol Data
base Size
M-5 Master Database
Caution:
Since the total number of characters available for the master symbol database is
3000
,
changes to the
Master Symbol Database Size
will re-allocate the number of characters available for
each master symbol and could cause existing master symbols to be deleted (except master symbol #1,
unless it also exceeds the size limitation).
The table below specifies the maximum number of characters available to each symbol according the
number of master symbols defined, from 1 to 30.
M-5-1 Master Symbol Database Size
Definition:
Number of Master Symbols
allows you to select
1
to
30
master symbols
for the master symbol database.
Serial Cmd:
<
K231,
master symbol number,master symbol data
>
Note:
You must follow this command with a save command
<A>
or
<Z>
.
Default:
1
Options:
1 to 30
Master Symbol
Number
Maximum
Characters
Master Symbol
Number
Maximum
Characters
# 1
3000
# 6
500
# 2
1500
# 7
428
# 3
1000
# 8
375
# 4
750
# 9
333
# 5
600
# 10
300
M-5-2 Enter Master Symbol Data
Usage:
Allows you to enter master symbol data for any enabled master symbol index
number (1 to 10), provided the total number of characters does not exceed
the maximum allowed.
Serial Cmd: <
K231,
master symbol number,master symbol data
>
Options:
Enter data for 1 to 10 symbols (any combination of ASCII text up to the max-
imum allowed.
For example, to enter data for master symbol 9, after making certain that
master symbol database size is enabled for 9 or more symbols, send
<K231,
9,data
>
.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex val-
ues.
Caution:
If no data is entered, the existing data will be deleted.
M-5-3 Request Master Symbol Data
Definition:
Returns master symbol data for any enabled master symbols from 1 to 10.
For example, to request master symbol # 5, enter
<K231
?,5
>
. The reader
transmits master symbol # 5 data in brackets in the following format:
<5/>
.
If no master symbol data is available, the output will be:
<5/>
.
Serial Cmd:
<
K231
?,master symbol number
>
Caution:
Be sure to add the
?
or you will delete the master symbol.
Note:
This command returns the number of master symbols if no number is
included.
Содержание V440-F
Страница 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Страница 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Страница 37: ...2 Quick Start 2 6 V440 F C Mount Code Reader User Manual V440 F Lens Selection Based on Focal Length...
Страница 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Страница 151: ...6 Application Settings 6 4 V440 F C Mount Code Reader User Manual 6 3 New New opens a new WebLink session...
Страница 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Страница 224: ...A 3 Appendices V440 F C Mount Code Reader User Manual A V440 F Cable and Accessory Specifications...
Страница 225: ...Appendices A 4 V440 F C Mount Code Reader User Manual V440 F Cable and Accessory Specifications continued...
Страница 239: ...Appendices A 18 V440 F C Mount Code Reader User Manual M12 to RS 232 Breakout 1 Meter or 3 Meters V430 WR 1M V430 WR 3M...
Страница 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Страница 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Страница 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Страница 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Страница 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Страница 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Страница 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Страница 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Страница 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Страница 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...