6-11
6 Application Settings
V440-F C-Mount Code Reader User Manual
6-9 Im
age
S
torag
e
6
Image Storage (Continued from Previous Page)
Stored Image Type
allows you to configure which images are stored to the destination device. Options are:
• Good Read:
Saves image(s) where the decoder reports a good read.
• No Read:
Saves image(s) where the decoder does not report a good read (default).
• Good Read and No Read:
Save both Good Read and No Read decoder reports.
• Match:
Save reports satisfying Match criteria.
• Mismatch:
Save reports satisfying Mismatch criteria.
• Match and Mismatch:
Save reports satisfying both Match and Mismatch criteria.
• All:
Save All reports.
Storage Mode
represents which image or images are stored. Options are:
• First Image in a Read Cycle:
Save first image that qualifies the
Stored Image Type (default)
.
• All Images in a Read Cycle:
Save all images that qualify the
Stored Image Type
.
Image File Format
allows you to select which file format to apply to the saved image. Options are:
• PNG – High Resolution:
Save images using .png format
(default)
.
• JPG – Low Resolution:
Save images using .jpg format.
• BMP – Direct Raw:
Save images using .bmp format.
Image Quality
is a sliding scale between
1%
and
100%
, where the higher the image quality, the more
space is required to store the image. The default setting is
90%
.
Image Scale
represents the amount of data compression applied to the stored image. Images with a
lower compression ratio require more storage space. Options are:
• 1:1 –
No data compression applied. Full image
(default)
.
• 2:1 –
Image compressed by 50%.
• 4:1 –
Image compressed by 75%.
• 8:1 –
Image compressed by 88%.
File Save Options
allow you to decide which type of report to save. Options are:
• Image:
Saves images
(default)
.
• Read Cycle Report:
Saves cycle reports.
• Image and Read Cycle Report:
Saves images and cycle reports.
Image Storage Location
is where images and reports are stored. Options are:
• RAM (Volatile Memory):
Images and cycle reports are saved to internal RAM drive
(default)
.
• Remote (FTP):
Images and cycle reports are saved to a remote FTP-connected device.
When the
Image Storage Location
setting is configured as RAM, all information is saved to a RAM
drive onboard the camera. This drive is volatile and all data is lost when the unit resets.
Содержание V440-F
Страница 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Страница 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Страница 37: ...2 Quick Start 2 6 V440 F C Mount Code Reader User Manual V440 F Lens Selection Based on Focal Length...
Страница 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Страница 151: ...6 Application Settings 6 4 V440 F C Mount Code Reader User Manual 6 3 New New opens a new WebLink session...
Страница 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Страница 224: ...A 3 Appendices V440 F C Mount Code Reader User Manual A V440 F Cable and Accessory Specifications...
Страница 225: ...Appendices A 4 V440 F C Mount Code Reader User Manual V440 F Cable and Accessory Specifications continued...
Страница 239: ...Appendices A 18 V440 F C Mount Code Reader User Manual M12 to RS 232 Breakout 1 Meter or 3 Meters V430 WR 1M V430 WR 3M...
Страница 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Страница 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Страница 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Страница 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Страница 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Страница 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Страница 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Страница 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Страница 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Страница 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...