105
NC Unit Error Logs
Section 10-1
Multiple
axis start
Multiple axis
start
8000
One of the following commands
was executed while the Data
Transferring Flag was ON:
DATA WRITE, DATA READ, or
DATA SAVE
Correct the ladder pro-
gram so that data
transfer (read or write)
or data save operation
is not executed while
the Data Transferring
Flag is ON. Execute
the data transfer or
data save operation
again.
The command will not
be executed.
If the last command
made before the error
was START, INDE-
PENDENT START,
ORIGIN SEARCH,
ORIGIN RETURN,
JOG, ABSOLUTE
MOVEMENT, RELA-
TIVE MOVEMENT, or
INTERRUPT FEED-
ING, the axis with the
error will be deceler-
ated to a stop.
When interpolation
operation is being
used, all interpolated
axes will be deceler-
ated to a stop.
If the error is gener-
ated during data trans-
fer (read or write) or
data saving, all axes
will be decelerated to
a stop.
Any operating axes
not specified above
will not be affected.
Memory
operation
Sequence
number error
8101
There was a memory operation
command and the Sequence
Number Enable Bit was ON, but
the specified sequence number
was outside the settable range (00
to 99).
Execute the command
again after checking
the sequence number.
The current START
command will not be
executed, but other
operating axes will not
be affected.
The Sequence Number Enable Bit
was OFF, or the FORCED INTER-
RUPT Bit was ON, when memory
operation was executed after the
power was turned ON or the NC
Unit was restarted, or after an ori-
gin search, origin return, or
present position preset.
Execute the command
again after changing
the turning ON the
Sequence Number
Enable Bit.
Change the ON timing
for the FORCED
INTERRUPT Bit.
The axis designations for the
specified sequence number’s
sequence data were all set to 0.
Execute the command
again after correcting
the sequence data.
The FORCED INTERRUPT Bit
was turned ON after a bank end
completion in memory operation.
Change the ON timing
for the FORCED
INTERRUPT Bit.
Speed error
8104
When positioning with memory
operation, the speed specified in
the sequence data was set to 0.
Execute the command
again after checking
the speed data and
sequence data to
make sure that the tar-
get speed is not 0.
The axis will be decel-
erated to a stop if the
error is detected dur-
ing positioning. Other
operating axes will not
be affected.
Group
Name
Code
Cause
Clearing method
Operation after error
Содержание SYSMAC W398-E1-1
Страница 1: ...23 5 7 21 0 18 Cat No W398 E1 1 SYSMAC WS02 NCTC1 E CX Position...
Страница 2: ......
Страница 3: ...WS02 NCTC1 E CX Position Operation Manual Produced July 2001...
Страница 4: ...iv...
Страница 10: ......
Страница 76: ......
Страница 80: ......
Страница 94: ......
Страница 100: ......
Страница 101: ...87 SECTION 9 Printing Data This section provides information about printing data 9 1 Printing Data 88...
Страница 104: ......
Страница 124: ......
Страница 126: ......
Страница 127: ...Cat No W398 E1 1 Note Specifications subject to change without notice 0675163 0A Printed in Japan 0701 3M...