95
NC Unit Error Logs
Section 10-1
Backlash com-
pensation
Backlash compensa-
tion error
1700
The axis parameters’ backlash
compensation setting is outside
the settable range (0 to 9,999
pulses).
In this condition, only the data
transfer (read or write) and data
save operations can be performed.
All of the axis parameters will be
returned to their default values.
After correcting the appropriate
axis parameters, reset the power
supply or restart the NC Unit.
Backlash compensa-
tion speed error
1710
The axis parameters’ backlash
compensation speed setting
exceeds the maximum speed set-
ting.
Software limits CW software limit
error
1800
The axis parameters’ CW software
limit setting is outside the settable
range (-1,073,741,823 to
1,073,741,823).
CCW software limit
error
1801
The axis parameters’ CCW soft-
ware limit setting is outside the set-
table range (-1,073,741,823 to
1,073,741,823).
Sensor inputs
Emergency stop
input
6000
An emergency stop signal has
been input.
After clearing the emergency stop
input, execute RELEASE PRO-
HIBIT/ERROR RESET.
For a limit input, execute
RELEASE PROHIBIT/ERROR
RESET and feed in the opposite
direction from the limit stop.
Check the axis parameters’ signal
type setting (N.C. or N.O.).
CW limit stop
6100
A CW limit input signal has been
input.
CCW limit stop
6101
A CCW limit input signal has been
input.
Group
Name
Code
Cause
Remedy
Содержание SYSMAC W398-E1-1
Страница 1: ...23 5 7 21 0 18 Cat No W398 E1 1 SYSMAC WS02 NCTC1 E CX Position...
Страница 2: ......
Страница 3: ...WS02 NCTC1 E CX Position Operation Manual Produced July 2001...
Страница 4: ...iv...
Страница 10: ......
Страница 76: ......
Страница 80: ......
Страница 94: ......
Страница 100: ......
Страница 101: ...87 SECTION 9 Printing Data This section provides information about printing data 9 1 Printing Data 88...
Страница 104: ......
Страница 124: ......
Страница 126: ......
Страница 127: ...Cat No W398 E1 1 Note Specifications subject to change without notice 0675163 0A Printed in Japan 0701 3M...