2-114
D
Connection Configuration and External Dimensions
For Servomotors without Brakes
R88A-CAWC
jjj
S-E
Servo Driver
Servomotor
R88D-WT
j
R88M-W
j
34.1
di
a.
For Servomotors with Brakes (only 230 VAC type Servomotor)
R88A-CAWC
jjj
B
Servo Driver
Servomotor
R88D-WT
j
R88M-W
j
37.3
di
a.
D
Wiring
For Servomotors without Brakes
R88A-CAWC
jjj
S-E cable connection
Cable
Connector plug:
MS3106B18-10S (DDK Ltd.)
Cable clamp:
MS3057-10A (DDK Ltd.)
Servomotor
Receptacle:
MS3102A18-10P (DDK Ltd.)
Cable: AWG14
×
4C UL2463
Servo Driver
Red
Servomotor
White
Blue
Green/Yellow
Phase-U
Phase-V
Phase-W
Symbol
M4 crimp
terminals
For Servomotors with Brakes (only 230 VAC type Servomotor)
R88A-CAWC
jjj
B cable connection
Cable
Connector plug:
MS3106B20-15S (DDK Ltd.)
Cable clamp:
MS3057-12A (DDK Ltd.)
Servomotor
Receptacle:
MS3102A20-15P (DDK Ltd.)
Cable: AWG14
×
6C UL2463
Servo Driver
Servomotor
Red
White
Blue
Green/Yellow
Black
Brown
Phase-U
Phase-V
Phase-W
Brake
Brake
Symbol
M4 crimp
terminals
For certain 400 VAC type Servomotor with brake a seperate braking cable is needed. Therefore it is
necessary to use both power cable for Servomotor without brake (R88A-CAW-
j
S-E) and braking
cable (R88A-CAWC
j
B-E).
R88A-CAWC
j
B-E is only used for wiring (2--CORE) the brake line and is applicable for all 400 VAC
type Servomotors.
Standard Models and Specifications
Chapter 2
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]