80
D
Timing for Run Command (RUN), Errors, Power Supply: Servomotor Stopped
Power on
Power off
Power supply
Brake interlock
signal
BKIR
Power to
motor
Run command
RUN
Alarm output
ALM
Motor rotational
speed
Approx. 10 ms
(See note 1.)
Brake command speed
(Cn-15)
Braking by dynamic brake
(When Cn-01 bit no. 6 = 0)
(See note 2)
Note 1. For the approximately 10 ms it takes from when the power to the Servomotor turns off until the
dynamic brake operates, the Servomotor rotates by momentum.
Note 2. If the Servomotor rotational speed falls below the speed set for the brake command speed
(Cn-15), or if the time set for brake timing 2 (Cn-16) elapses after the Servomotor stops receiv-
ing power, the brake interlock signal (BKIR) will turn OFF.
Operation
Chapter 3