120
Alarm
display
Countermeasures
Probable cause
Condition when error oc-
curred
Error content
cpf00
Parameter Unit
transmission er-
Occurred when power was
turned on.
•
Connector contact faulty.
•
Insert connectors correct-
ly.
a s
ss o e
ror 1
u ed o
•
Internal element is mal-
functioning.
•
Reset and operate again.
•
Servo Driver defective.
•
Replace the Servo Driver.
•
Parameter Unit is defec-
tive.
•
Cable is broken (R88A-
PR02U).
•
Replace the Parameter
Unit.
cpf01
Parameter Unit
transmission er-
Occurred while the Parame-
ter Unit was being used.
•
Connector contact faulty.
•
Insert connectors correct-
ly.
a s
ss o e
ror 2
e U
as be g used
•
Internal element is mal-
functioning.
•
Reset and operate again.
•
Internal element is dam-
aged.
•
Cable is broken (R88A-
PR02U).
•
Replace the Servo Driver.
•
Replace the Parameter
Unit.
Application
Chapter 4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com