108
H
Servomotor Parameter Checking Operation
The items in parentheses in the following explanation indicate operations using the Handy-type Param-
eter Unit.
0
y
f
c
n
-
0
0
0
0
-
0
4
[1]
[3]
[5]
[5]
Data
[4]
0
0
0
2
0
0
0
[6]
[7]
DATA
Indicates settings mode.
System check mode
[2]
1. Press the MODE/SET Key to switch to the settings mode.
2. Using the Up and Down Keys, set parameter number “00.” (System check mode)
3. Press the DATA Key to display the setting of Cn-00.
4. Using the Up and Down Keys, change the setting to “04.” (Servomotor parameter check)
5. Press the MODE/SET Key, and check the Servomotor parameters in order.
6. Press the MODE/SET Key to display special specifications in hexadecimal.
7. Press the MODE/SET Key to return to the data display for the system check mode.
H
Parameter Display Contents
D
Servomotor Parameters
f
0
0
0
2
Motor capacity
9E:
30 W
b2:
50 W
01: 100 W
02: 200 W
03: 300 W
04: 400 W
08: 750 W
Motor type 00: 200-V type
41: 100-V type
D
Special Specifications
0
y
0
0
0
User specifications number (hexadecimal display)
Application
Chapter 4