39
•
If the control power supply wiring is long, noise resistance can be improved by adding 1-
µ
F laminated
ceramic capacitors between the control power supply and ground at the Servo Driver input section
and the controller output section.
•
For encoder output (A, B, and Z phase) lines, be sure to use twisted-pair shielded cable, and connect
both ends of the shield wire to ground.
•
Wiring must be 1 m or less when using open-collector outputs.
System Design and Installation
Chapter 2