Section 2 NS Series Functions
2-4 System Memory
2-34
NS Series Programming Manual
$SB54 is turned ON when level 1 or higher authentication is completed. $SB54 is turned OFF when
authentication is cancelled.
$SB55 is turned ON when level 2 or higher authentication is completed. $SB55 remains OFF during
level 1 and is turned OFF when authentication is cancelled.
$SB56 is turned ON when level 3 or higher authentication is completed. $SB56 remains OFF during
level 2 or lower and is turned OFF when authentication is cancelled.
$SB57 is turned ON when level 4 or higher authentication is completed. $SB57 remains OFF during
level 3 or lower and is turned OFF when authentication is cancelled.
$SB58 is turned ON when level 5 or higher authentication is completed. $SB58 remains OFF during
level 4 or lower and is turned OFF when authentication is cancelled.
R
R
R
e
e
e
f
f
f
e
e
e
r
r
r
e
e
e
n
n
n
c
c
c
e
e
e
♦
The status flags will not operate if the
Function mode
is set to enable a password without
levels in the Password Setting Dialog Box. Refer to
2-8-15 Passwords (Extension Tab)
for
details on password settings.
System bit memory ($SB) can be allocated to the following areas on the host PLC.
Symbol C-series
PLCs Allocation
CVM1/CV-series
PLCs
Allocation CS/CJ-series PLCs Allocation
None
I/O area (IR)
I/O area (CIO)
I/O area (CIO)
H HR
Area
HR Area
A AR
Area
AR Area
×
AR Area
L LR
Area
LR Area (See note 1.)
T
Timer present
values
×
Timer present
values
×
Timer present values
×
TU
Timer Completion
Flags
×
C
Counter present
values
×
Counter present
values
×
Counter present
values
×
CU
Counter Completion
Flags
×
W
Work Area
TK
Task Flags
×
D DM
Area
DM Area
DM Area
E
EM Area
(See note 2.)
(Current bank)
EM Area
(Current bank)
EM Area
(Current bank)
E0_
EM Area
Bank 0
E18_
EM Area
Bank 18
Note 1. LR 00000 to LR 00199 are converted to and used as I/O area words CIO 01000 to CIO 01199.
2. C200HX/HG/HE-E/-ZE PLCs are the only C-series PLCs that support the EM Area (EM). All bits in the
AR Area for CVM1/CV-series PLCs are allocated for system functions and cannot be used for any other
application.
The ranges for each area vary with the PLC model. Refer to
Appendix 3 PLC Memory Areas
. Refer to
System Settings and Project Properties
in the
CX-Designer Online Help
for details on allocation meth-
ods.
Set a BOOL variable with 64 elements when allocating a tag.
Содержание NS -
Страница 2: ......
Страница 12: ...Contents vi NS Series Programming Manual...
Страница 46: ...Section 1 Overview 1 5 Procedure before Operation 1 33 NS Series Programming Manual...
Страница 590: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual...
Страница 604: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual...
Страница 640: ...Section 5 Troubleshooting and Maintenance 5 2 Error Messages 5 35 NS Series Programming Manual...
Страница 680: ...Appendices Appendix 6 Additional NS Series Functions A 39 NS Series Programming Manual...
Страница 682: ......
Страница 683: ......