Section 3 Using PTs
3-4 Changing Numeral and Character String Display
3-13
NS Series Programming Manual
1. The contents display is placed in screens using CX-Designer.
2. Select
the
Display a string
checkbox on the General Tab Page when making the contents display
property settings.
3. Set the
No. of Contents
and
Address for switching Contents
on the Edit Contents toolbar in
CX-Designer.
4.
Enter the contents number to be edited in the input field for
Contents No.
on the Edit Contents tool
bar.
5. Select
Contents Display
. Press the
Space
Key and enter the string to be displayed.
6. Repeat steps 4 and 5 for the number of contents to be set.
Refer to
2-19 Machine Navigator Function
for details.
Using Command Buttons with Key Button Function
1. Select
function - Key button
on the Command Button General Tab Page.
2. Select the destination.
Indirect Specification of Target Strings
Specify the address where the numeral or string data is stored and the number of transmit words. Se-
lect
Transmit type - Indirect specification of string
and specify the address and number of words.
ab
Host
If more characters than are set for the character string display and input object are transferred, only the
set number of characters will actually be transferred. For example, if 10 characters are transferred to a
character string and display object to which only 3 characters are set, only three characters will actu-
ally be transferred.
Transferring Label Strings Set to Command Buttons
Select
Transmit type - Label string
.
Transferring Specified Strings
Select
Transmit type - specified string
and set the string to be transferred.
Transfers string “abcde”.
Changing Label Strings by Switching Labels
Multiple strings can be set to functional object labels using CX-Designer.
The functional object label display can then be changed by switching the labels.
1. Set the number of label switches and the name of each corresponding label in the Project Property
Window’s Switch Label Tab Page. (Select
PT - Project Properties
and click the
Switch Label
Tab.)
Содержание NS -
Страница 2: ......
Страница 12: ...Contents vi NS Series Programming Manual...
Страница 46: ...Section 1 Overview 1 5 Procedure before Operation 1 33 NS Series Programming Manual...
Страница 590: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual...
Страница 604: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual...
Страница 640: ...Section 5 Troubleshooting and Maintenance 5 2 Error Messages 5 35 NS Series Programming Manual...
Страница 680: ...Appendices Appendix 6 Additional NS Series Functions A 39 NS Series Programming Manual...
Страница 682: ......
Страница 683: ......