Section 2 NS Series Functions
2-12 Display and Input Objects
2-254
NS Series Programming Manual
No. Setting
Details
1 Object
Comment
Sets an explanatory comment for the pasted object.
(Up to 32 characters.)
2 Numeral
display type
Sets the numeral display type.
Display type
Select from the following 4 display formats.
Decimal
Hexadecimal
Binary
Octal
Storage type
Select from the following 11 storage types.
INT signed, 1 word
UINT unsigned, 1 word
DINT signed, 2 words
UDINT unsigned, 2 words
REAL (real number) (See note 1.)
BCD2 (See note 1.) unsigned, 1 word
BCD2 (See note 1.) unsigned, 2 words
BCD1 signed (leftmost digit: F), 1 word (See note 1.)
BCD1 signed (leftmost digit: F), 2 words (See note 1.)
BCD2 signed (leftmost bit: 1), 1 word (See note 1.)
BCD2 signed (leftmost bit: 1), 2 words (See note 1.)
2
Specifies the number of display digits for the integer and decimals.
The numeral display can be changed to any format.
Example: When set to 2 integers and 1 decimal place:
Actual value
Numeral display
9.51
99.51
999.51
9.5
99.5
99.5
Integer
Decimal
As shown above, digits after the specified number of integers are ignored.
The decimal is rounded to the specified number of digits.
Fill blank digits
with zeros (See
note 2.)
Inserts zeros to fill the specified number of display digits. For example, if the number of dis-
play digits is set to 4 and the value is 1, the display will be 0001.
3
Button position
Sets the position for the + and – Buttons.
4
Address
Sets the destination address accessed and written by thumbwheel switches.
5 Units
and
scales
Scales the contents of the communications address using the set scale value.
Click
Limit check after scale conversion
to check the upper and lower limits after the contents
have been converted using the set scale. Refer to
Unit and Scale
in
2-8 Common Functional
Object Functions
for information on units and scales.
Note 1. Can be selected only when display type set to
Decimal
.
2. When set to
Fill blank digits with zeros
, 9.51 in the example in the table will be displayed as 09.51.
N
N
N
o
o
o
t
t
t
e
e
e
♦
When pasting CX-Designer functional objects, use the numeral 9 and create a number such as
9,999.99 to set the number of display digits by default.
♦
For real numbers, 7 digits are valid. If the number of display digits is set higher than 7, error will
occur when numbers are input and the values may change for digits that are not input.
♦
If a value that cannot be displayed at the address is stored, e.g., 10 (a binary value) has been
stored when the display type is BCD, # will be displayed for every digit. When this happens, the +
and – Buttons cannot be used to change the value. Use the PLC or another functional object to
reset the value.
♦
Units cannot be displayed for thumbwheel switches.
♦
The scale for a thumbwheel switch must be set to a power of 10, and the offset must be set to 0. If
any other values are set, the thumbwheel switch many not operate properly.
Содержание NS -
Страница 2: ......
Страница 12: ...Contents vi NS Series Programming Manual...
Страница 46: ...Section 1 Overview 1 5 Procedure before Operation 1 33 NS Series Programming Manual...
Страница 590: ...Section 3 Using PTs 3 12 Function Key Settings NS15 Only 3 35 NS Series Programming Manual...
Страница 604: ...Section 4 Using Functions 4 1 Application 4 13 NS Series Programming Manual...
Страница 640: ...Section 5 Troubleshooting and Maintenance 5 2 Error Messages 5 35 NS Series Programming Manual...
Страница 680: ...Appendices Appendix 6 Additional NS Series Functions A 39 NS Series Programming Manual...
Страница 682: ......
Страница 683: ......