8.5 Maintaining and Replacing Batteries
Docking Station Contacts
The two docking station contacts need occasional cleaning. The suggested interval is 3 – 6
months, depending on frequency of charging.
WARNING:
Unplug power from the docking station before starting. Remove
the charger’s power cord.
Clean the contacts with Isopropyl alcohol.
CAUTION:
Do not lubricate the docking station paddle, which will reduce its
life.
8.5 Maintaining and Replacing Batteries
Maintaining Batteries
l
Every six months, inspect batteries (both stored and in-use) for damage or leaks.
If a battery is found to be leaking, do not expose it to water. If possible, submerge it in
mineral oil.
Contact your local Omron Support immediately for disposal instructions.
l
Store batteries upright at (one month) +5 to 45°C (41 to 113°F); (one year) 20 to 25°C (68
to 77°F).
l
Every six months, charge stored batteries to a full charge.
Replacing the Battery
The battery is expected to last for approximately ≥ 2000 recharge cycles.
NOTE:
There are no user-serviceable parts inside the battery case. Do not open it.
WARNING:
Replace the battery only with a Omron Adept Technologies, Inc.
factory-supplied battery.
Dispose of the battery according to all local and national environmental regulations regarding
electronic components.
WARNING:
Follow appropriate ESD procedures during the
removal/replacement phases.
Содержание LD Platform
Страница 1: ...I611 E 02 LD Platform User s Guide...
Страница 8: ......
Страница 37: ...Chapter 3 Setup Figure 3 15 E Stop Jumper on LD Platform Core 11970 000 Rev H1 LD Platform OEM User s Guide 37...
Страница 44: ......
Страница 70: ...70 LD Platform OEM User s Guide 11970 000 Rev H1 6 2 Payload Bay Connections Figure 6 7 E Stop Chain Diagram...
Страница 98: ......
Страница 130: ......
Страница 139: ......