110
LD Platform OEM User's Guide
11970-000 Rev H1
8.6 Replacing Non-Periodic Parts
Roller
Switch
Figure 8-7. Docking Station Roller and Switch Locations
Docking Station AC Power Fuse
NOTE:
The current version of the docking station uses a thermal fuse, built into the
power switch. There are no user-serviceable fuses.
NOTE:
The following procedure applies only to legacy docking stations.
The only user-serviceable fuses are in the docking station. The two external AC fuses are loc-
ated between the power switch and the AC power plug.
Symptoms: When the docking station is switched on, the blue power light does not come on.
(Verify that the unit is plugged into AC power.)
WARNING:
Unplug power from the docking station before starting. Remove
the power cord from the charger.
Remove the fuse assembly by squeezing the two tabs toward each other, and pulling it away
from the docking station. See the following figure.
Содержание LD Platform
Страница 1: ...I611 E 02 LD Platform User s Guide...
Страница 8: ......
Страница 37: ...Chapter 3 Setup Figure 3 15 E Stop Jumper on LD Platform Core 11970 000 Rev H1 LD Platform OEM User s Guide 37...
Страница 44: ......
Страница 70: ...70 LD Platform OEM User s Guide 11970 000 Rev H1 6 2 Payload Bay Connections Figure 6 7 E Stop Chain Diagram...
Страница 98: ......
Страница 130: ......
Страница 139: ......