![Omron LD Platform Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/omron/ld-platform/ld-platform_user-manual_743974063.webp)
Chapter 6: Connectivity
Parameter
Value
Operational current range 0 to 7.5 mA
OFF state current range
0 to 0.5 mA
ON state current range
1.0 to 7.5 mA
Impedance (V
in
/I
in
)
3.9 kΩ minimum
Current at V
in
= +24 VDC I
in
≤ 6 mA
NOTE:
The input current specifications are provided for reference. Voltage sources
are typically used to drive the inputs.
Supplied Equipment
User-Supplied Equipment
Input_1.1
Part Present Sensor
1
Input_1.2 2
Input_1.3 3
Input_1.4 4
VBAT_IO_OUT1
GND
Bank 1
Common
Bank 4
Common
5
40
41
Input_4.1 16
Input_4.2 17
Input_4.3 18
Input_4.4 19
20
42
GND
37
VBAT_IO_OUT4
Wiring
Terminal
Block
Typical User
Input Signal
Note: all Input signals
can be used for either
sinking or sourcing
configurations.
Bank 1 configured f
or
Sinking (NPN) Inputs
Bank 4 configured f
or
Sourcing (PNP) Inputs
(equivalent circuit)
Input Bank 4
Input Bank 1
Input Bank 3
Input Bank 2
Figure 6-3. Typical Digital Input Wiring Example
Table 6-1. Digital Output Specifications
Parameter
Value
Power supply voltage range
5 - 30 VDC
Operational current range, per channel I
out
≤ 500 mA
ON state resistance (I
out
= 0.5 A)
R
on
≤ 0.14 Ω @ 85°C
Output leakage current
I
out
≤ 5 μA
DC short circuit current limit
0.7 A ≤ I
LIM
≤ 1.7 A
11970-000 Rev H1
LD Platform OEM User's Guide
63
Содержание LD Platform
Страница 1: ...I611 E 02 LD Platform User s Guide...
Страница 8: ......
Страница 37: ...Chapter 3 Setup Figure 3 15 E Stop Jumper on LD Platform Core 11970 000 Rev H1 LD Platform OEM User s Guide 37...
Страница 44: ......
Страница 70: ...70 LD Platform OEM User s Guide 11970 000 Rev H1 6 2 Payload Bay Connections Figure 6 7 E Stop Chain Diagram...
Страница 98: ......
Страница 130: ......
Страница 139: ......