4 Monitoring the Temperature in Control Panel with the Main Unit and the Software Tool
4 - 24
K6PM-TH Thermal Condition Monitoring Device User’s Manual (H231)
• When automatic setting is set for the alarm threshold
Click the
Calculation
Button under the Threshold set tab. The following tab page is displayed.
Enter the "Max. ambient temperature" in the following range.
Setting range: 0.0 to 80.0 (°C), 32.0 to 176.0 (°F)
Ideally, perform the operation until the ambient temperature stabilizes, and thereafter, enter the maxi-
mum ambient temperature in view of temperature variation in summer time.
Click the
Calculation
Button. The alarm threshold is automatically calculated.
Note The maximum ambient temperature used in the automatic calculation of threshold is displayed in "Max.
ambient temperature" under the
Threshold set
Tab.
• When the alarm threshold automatic setting parameter is to be corrected, or when setting is per-
formed manually
Enter each "Threshold 1" and "Threshold 2" of the "Temp." and "Temp. Gap" for each segment, and
the “Threshold 1" and "Threshold 2" of the sensor internal temperature within the range specified
below.
Threshold 1 and Threshold 2: 0.0 to 999.9 (°C) or 0.0 to 999.9 (°F)
When setting the alarm threshold, if you set a value exceeding 200.0°C (392°F), an alarm will not be
output.
4
Click the
Write
Button to write the threshold setting to the Main Unit.
5
If you click the
Back
Button, the display will return to the
Monitoring K6PM
Screen.
Precautions for Safe Use
The threshold automatic setting function of alarm temperature automatically calculates the
threshold based on the past temperature data up to the time when the
Calculation
Button was
clicked. Therefore, if a change in the installation environment and operating status, etc. occurs
due to the effect of the air-cooling fan, or the opening/closing of the control panel door, click the
Calculation
Button again to reset the alarm threshold.
To set the alarm threshold in more detail, it is recommended to set the threshold individually for
each segment without using the threshold automatic setting function of alarm temperature.
Enter the max. ambient temperature
for the base internal temperature of the sensor.
Click during calculation.
Содержание K6PM-TH
Страница 56: ...2 Installation and Wiring 2 20 K6PM TH Thermal Condition Monitoring Device User s Manual H231...
Страница 76: ...3 Initial Setting 3 20 K6PM TH Thermal Condition Monitoring Device User s Manual H231...
Страница 156: ...7 Troubleshooting 7 8 K6PM TH Thermal Condition Monitoring Device User s Manual H231...
Страница 195: ...I 1 I K6PM TH Thermal Condition Monitoring Device User s Manual H231 Index...
Страница 197: ......