Operation manual
G9SR
Page 18 of 79
5.4.1
Automatic Restart with dynamic input testing
Power
supply
circuit
Safety
Input 1
Safety
Input 2 Restart
EDM
Safety Output
Control
Auxiliary Output
Control
T32
T31
T22
T21
T12
A1
A2
14
24
44
T11
Function setting:
DIP Switch 1 ON = Automatic Restart
DIP Switch 2 ON = Dynamic input testing Enabled
Description:
E-Stop pushbutton connected to T12 and T22
Remarks:
Wiring is using the dynamic test pulses.
Applicable up to Ple acc. EN ISO 13849-1
Output connections and EDM not shown in this schematic
+24V
0V
Fuse
5A F
5.4.2
Automatic Restart without dynamic input testing
Power
supply
circuit
Safety
Input 1
Safety
Input 2 Restart
EDM
Safety Output
Control
Auxiliary Output
Control
T32
T31
T22
T21
T12
A1
A2
14
24
44
T11
Function setting:
DIP Switch 1 ON = Automatic Restart
DIP Switch 2 OFF = Dynamic input testing Disabled
Description:
E-Stop pushbutton connected to T12 and T22
Remarks:
Applicable up to Pld acc. EN ISO 13849-1
Output connections and EDM not shown in this schematic
+24V
0V
Fuse
5A F