Operation manual
G9SR
XVI
WARNING
Electric shock may occur. Do not touch any terminals while power is being
supplied.
Serious injury may possibly occur due to loss of required safety functions.
Do not use the G9SR Safety Relay's test outputs or standard outputs as
safety outputs.
Serious injury may possibly occur due to loss of required safety functions.
Do not use indicators on the G9SR Safety Relay for safety operations.
Serious injury may possibly occur due to breakdown of safety outputs or
test outputs. Do not connect loads beyond the rated values to the safety
outputs and test outputs.
Serious injury may possibly occur due to loss of required safety functions.
Wire the G9SR series Controller properly so that the 24VDC line does NOT
touch the outputs accidentally or unintentionally.
Do not try to disassemble, repair, or modify this product. Doing so may
cause the safety functions to stop working properly.
Do not use the G9SR Safety Relays in environments where flammable or
explosive gases are present. Doing so may result in an explosion.
Do not use the auxiliary output for safety applications.
Do not connect the 0V line to PE.
Serious injury may possibly occur due to loss of required safety functions.
Serious injury may possibly occur due to loss of required safety functions.
Perform user testing and confirm that all of the G9SR Safety Relay’s
configuration data and operation is correct before starting system operation.
Serious injury may possibly occur due to loss of required safety functions.
When replacing a G9SR Safety Relay, confirm the model of the Controller
is correct and configure the replacement Controller suitably and confirm
that it operates correctly.
Serious injury may possibly occur due to loss of required safety functions.
Use devices and parts related to safety functions according to legal
regulations in the applicable country. Use certified items compliant with
safety standards corresponding to the intended application.
Perform daily and 6-monthly inspections for the G9SR Safety Relays.
Otherwise, the system may fail to work properly, resulting in serious injury.
Содержание G9SR
Страница 1: ...ZX T Series Cat No J12E EN 03 G9SR Safety Relays OPERATION MANUAL G9SR BC G9SR AD G9SR EX...
Страница 34: ...Operation manual G9SR Page 8 of 79 3 1 Test the OFF behaviour...
Страница 35: ...Operation manual G9SR Page 9 of 79 3 2 Test the ON behaviour...
Страница 102: ...Operation manual G9SR Page 76 of 79 My notes...