1.2.2
G9SR-AD
The G9SR-AD has a double channel safety input that can be
used in E-Stop, door monitoring applications or applications
with opto-electronic safety sensors.
The G9SR-AD has safety relay outputs for
Max. 4A AC1 @ 250V *
Max. 5A AC15 @ 250V
Max. 4A DC1 @ 30V *
Max. 5A DC13 @ 30V
*
See also § 4.2
For more details see also:
Chapter 4
on page 10.
The G9SR-AD can operate standalone or in a system with
•
up to two additional G9SR-BC as input expansion
•
up to three G9SR-EX as additional safety relay outputs.
See also:
Chapter 7
1.2.3
G9SR-EX
The G9SR-EX operates as an output extension to a G9SR-AD.
The G9SR-EX has safety relay outputs for
Max. 4A AC1 @ 250V *
Max. 5A AC15 @ 250V
Max. 4A DC1 @ 30V *
Max. 5A DC13 @ 30V
*
See also § 4.2
For more details see also:
Chapter 4
on page 10.
The output signals of the G9SR-
EX□
-T90-
□
unit can be switched with 16 timing pre-
sets for an ON-delay and 16 timing pre-sets for an OFF-delay.
See also:
Chapter 8
on page 33.