- 3 -
- 4 -
- 1 -
- 2 -
D141223/150116
Specifications
Wiring diagram
BISTABLE RELAY
BIS-408
power supply
V AC
contact / load current
current L control pulse
< mA
response delay
0.1÷0.2s
supply signalling
green LED
power consumption
standby
0.
W
on
0.6W
working temperature
-
÷50°C
terminal
screw terminals
tightening torque
0.4Nm
mounting
in the Ø60 flush-mounted box
ingress protection
I 20
100÷265
AC-1
1NO / <16A
5
15
25
dimensions
Ø
54 (□48×43mm), h= 20mm
P
2.5mm
²
U
2000W
1000W
1250W
incandescent
fluorescent
energy-saving
halogen
LED
500W
250W
Power table
The above data are indicative and will depend to a large extent on
the design of a specific receiver (especially for LED bulbs, energy
saving lamps, electronic transformers and pulse power supplies),
switching frequency and working conditions.
For more information visit: www.fif.com.pl.
Electronic bistable impulse relay allows switching of lighting or
other equipment from several different points of using the control
buttons are connected in parallel.
L
N
N
L
BIS
The receiver is after the current pulse caused by pressing any
(bell) connected to the relay. Exclusion the receiver will be the
next pulse.
The relay does not have a "memory" of the contact position,
ie. in the case of power failure and the subsequent return, contact
the relay will be set in the off.
This prevents the automatic switching of loads without
supervision after a prolonged power failure.
5
9 0 8 3 1 2
5 9 8 2 8 2
L
N
2
3
5
L
1
N
L
6
4
N
PWR
L
N
Functioning
WARRANTY.
The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase. Contact your
dealeror directly with us. More
information how to make a compliant can
be found on the website:
www.fif.com.pl/reklamacje
Do not dispose of this device to a garbage bin with other unsorted waste!
In accordance with the Waste Electrical and Electronic Equipment Act
any household electro-waste can be turned in free of charge and in any
quantity to a collection point established for this purpose, as well as to the
store in the event of purchasing new equipment (as per the old for new rule,
regardless of brand). Electro-waste thrown in the garbage bin or abandoned
in the
bosom of nature pose a threat to the environment and human health.
Purpose
Assembly
1. Disconnect the power supply.
2. The relay mounted in flush-mounted box.
3. Connect the power supply to a group of PWR: L phase wire to
terminal 5 or 6. The N neutral to terminal 3 or 4.
4. At the same momentary switches connected to terminal 1 and
the L phase conductor.
5. Powered receiver connected in series to terminal 2 and the N
neutral conductor.
Note!
BIS-408 can be used with illuminated buttons.
F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND