3 - 19
3 Communications Data for CompoWay/F
E5
C-T Digital Temperature Controllers Programmable Type Communications Manual (H186)
3-1 V
ariab
le A
rea (Setting
Ran
g
e) List
3
C3 (83)
0097
Area
H'00000000 (0: DM or D data registers)
H'00000001 (1: EM0 or W link registers)
H'00000002 (2: EM1 or R file registers)
H'00000003 (3: EM2 or ZR file registers)
H'00000004 (4: EM3)
H'00000005 (5: EM4)
H'00000006 (6: EM5)
H'00000007 (7: EM6)
H'00000008 (8: EM7)
H'00000009 (9: EM8)
H'0000000A (10: EM9)
H'0000000B (11: EMA)
H'0000000C (12: EMB)
H'0000000D (13: EMC)
H'0000000E (14: EMD)
H'0000000F (15: EME)
H'00000010 (16: EMF)
H'00000011 (17: EM10)
H'00000012 (18: EM11)
H'00000013 (19: EM12)
H'00000014 (20: EM13)
H'00000015 (21: EM14)
H'00000016 (22: EM15)
H'00000017 (23: EM16)
H'00000018 (24: EM17)
H'00000019 (25: EM18)
*
Information after “or” is applicable when the Protocol
Setting parameter is set to MCP4.) Also, all set val-
ues of 4 and higher specify D data registers.
Communi
cations
setting
C3 (83)
0098
First Address
Upper Word
H'00000000 to H'00000063 (0 to 99)
C3 (83)
0099
First Address
Lower Word
H'00000000 to H'0000270F (0 to 9999)
C3 (83)
009A
Receive Data Wait
Time
H'00000064 to H'0000270F (100 to 9999)
C3 (83)
009B
Communications
Node Number
H'00000000 to H'00000063 (0 to 99)
C3 (83)
009C
Upload Setting 1
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
009D
Upload Setting 2
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
009E
Upload Setting 3
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
009F
Upload Setting 4
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A0
Upload Setting 5
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A1
Upload Setting 6
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A2
Upload Setting 7
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A3
Upload Setting 8
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A4
Upload Setting 9
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A5
Upload Setting 10
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A6
Upload Setting 11
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A7
Upload Setting 12
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A8
Upload Setting 13
H'00000000 to H'000000B3 (0 to 179)
C3 (83)
00A9
Download Setting
1
H'0000001E to H'000000B3 (30 to 179)
C3 (83)
00AA
Download Setting
2
H'0000001E to H'000000B3 (30 to 179)
C3 (83)
00AB
Download Setting
3
H'0000001E to H'000000B3 (30 to 179)
Variable
type
Address
Parameter name
Setting (monitor) value
Level
Содержание E5CC-T
Страница 2: ......
Страница 14: ...Revision History 12 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186...
Страница 176: ...7 Component Communications 7 8 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186...
Страница 181: ...Index 1 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186 I Index...
Страница 184: ...Index 4 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186...
Страница 185: ......