3 - 9
3 Communications Data for CompoWay/F
E5
C-T Digital Temperature Controllers Programmable Type Communications Manual (H186)
3-1 V
ariab
le A
rea (Setting
Ran
g
e) List
3
C3 (83)
0007
PID ON/OFF
H'00000000 (0): ON/OFF
H'00000001 (1): 2 PID control
Initial
setting
C3 (83)
0008
Standard or
Heating/Cooling
H'00000000 (0): Standard
H'00000001 (1): Heating and cooling
C3 (83)
000A
Control Period
(Heating)
H'FFFFFFFE (
−
2): 0.1 s
H'FFFFFFFF (
−
1): 0.2 s
H'00000000 (0): 0.5 s
H'00000001 to H'00000063 (1 to 99)
C3 (83)
000B
Control Period
(Cooling)
H'FFFFFFFE (
−
2): 0.1 s
H'FFFFFFFF (
−
1): 0.2 s
H'00000000 (0): 0.5 s
H'00000001 to H'00000063 (1 to 99)
C3 (83)
000C
Direct/Reverse
Operation
H'00000000 (0): Reverse operation
H'00000001 (1): Direct operation
C3 (83)
000D
Alarm 1 Type
H'00000000 (0):
Alarm function OFF
H'00000001 (1):
Upper and lower-limit alarm
H'00000002 (2):
Upper-limit alarm
H'00000003 (3):
Lower-limit alarm
H'00000004 (4):
Upper and lower-limit range alarm
H'00000005 (5):
Upper and lower-limit alarm with
standby sequence
H'00000006 (6):
Upper-limit alarm with standby
sequence
H'00000007 (7):
Lower-limit alarm with standby
sequence
H'00000008 (8):
Absolute-value upper-limit alarm
H'00000009 (9):
Absolute-value lower-limit alarm
H'0000000A (10): Absolute-value upper-limit alarm with
standby sequence
H'0000000B (11): Absolute-value lower-limit alarm with
standby sequence
H'0000000C (12): LBA (Loop Burnout Alarm)
H'0000000D (13): PV change rate alarm
H'0000000E (14): SP absolute-value upper-limit alarm
H'0000000F (15):
SP absolute-value lower-limit alarm
H'00000010 (16): MV absolute-value upper-limit alarm
H'00000011 (17): MV absolute-value lower-limit alarm
C3 (83)
000E
Alarm 2 Type
H'00000000 to H'00000011 (0 to 17)
Note: Same settings as the Alarm 1 Type. However, the
LBA (loop burnout alarm) cannot be set.
C3 (83)
000F
Alarm 3 Type
H'00000000 to H'00000011 (0 to 17)
Note: Same settings as the Alarm 1 Type. However, the
LBA (loop burnout alarm) cannot be set.
Variable
type
Address
Parameter
name
Setting (monitor) value
Level
Содержание E5CC-T
Страница 2: ......
Страница 14: ...Revision History 12 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186...
Страница 176: ...7 Component Communications 7 8 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186...
Страница 181: ...Index 1 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186 I Index...
Страница 184: ...Index 4 E5 C T Digital Temperature Controllers Programmable Type Communications Manual H186...
Страница 185: ......