Appendix B
Error Messages
100
Error message
Error processing
Specified slave has valid IN Data. To edit,
define valid IN Block.
The Create Master Parameters or Edit Device Parameters command
could not allocate I/O memory to a Slave that requires both output and
input data because there is no input memory block. Define a usable
input memory block to edit the parameters.
Specified slave has valid OUT Data. Before
registering, define valid OUT Memory Block.
The Master parameter wizard could not allocate I/O memory to a
Slave that requires output data because there is no output memory
block. Define a usable output memory block to register the Slave.
Specified slave has valid OUT Data. To edit,
define valid OUT Block.
The Create Master Parameters or Edit Device Parameters command
could not allocate I/O memory to a Slave that requires both output and
input data because there is no output memory block. Define a usable
output memory block to edit the parameters.
Specified file or device can not be accessed, or
specified service be supported.
Either the specified file/device doesn’t exist or the specified command
isn’t supported. Check the file/device.
Either an error occurred during communications or the specified
command isn’t supported. Check that the other node is operating
properly.
Also, verify that the Configurator’s baud rate matches the other node’s
baud rate and check for wiring problems.
Specified file can not be used for this function.
The specified file type is incorrect. Specify the correct file.
Specified file can not be used for this device.
Wrong unit type or wrong corresponding PLC.
The specified parameter file was created for a different model. Specify
the correct file.
Can not allocate all devices to specified
memory block.
The output area or input area was made too small (not enough
words), so the Master parameter wizard couldn’t allocate I/O to all of
the Slaves. Change the memory block settings.
Part or all of specified area Allocated to other
device.
Part or all of the specified area has already been allocated to another
device. Either allocate a different area or change the other device’s
I/O allocation.
Specified word located in setup impossible
area.
It isn’t possible to set the specified words. Set another area.
Setup out of specified block or setup Allocated
to setup impossible area removed.
Due to a change in memory block settings, all or part of the existing
allocation couldn’t be allocated within the block. Reassign the I/O
allocation within the current area.
Slave Allocated to Node Address of Self Master
Unit or Configurator.
A Slave device is allocated to the node address of the Configurator or
a Master Unit. Correct the allocation.
Because usable printer has not been set,
process can not be continued.
A usable printer hasn’t been set. Register the printer.
Already set to specified mode.
* The service can’t be executed because it is already set to the
specified mode.
Other device already Allocated.
The area is already allocated to another device. Either allocate
another area or change the existing device’s allocation.
Can not set all blocks to “Not Used.”
All of the memory blocks can’t be set to “Not Used.” Enable at least
one of the blocks.
Out of setup possible maximum number of
words.
The specified Master parameter settings exceed the specified PC’s
maximum number of words usable during remote I/O communications.
Setup possible parameters not exist.
The specified device has no parameters that can be set.
Can not read selected files.
There are too many files so some of the files could not be read.
Reduce the number of files.
Less than 2 target masters selected.
Masters were not selected correctly for an I/O allocation duplication
check. Select two or more Masters.
Too large data.
* The other node attempted to transmit too much response data.
Reduce the requested data size.
Too large data.
* The other node attempted to receive too much data. Reduce the
transmitted data size.
Wrong Data.
The specified data is incorrect.
Data value not match with Data Size.
The specified data does not match the data size. Set correct data.
Wring Data Format.
The data format is incorrect. Specify with the correct format.
Device not selected.
A target device hasn’t been selected. Select a target device.