3 - 23
3 Network Startup
CompoNet Communications Unit User’s Manual (I582-E1)
3-2
Network C
onf
igu
ra
tion
3
3-
2-5 R
egistra
tion
Table
Configuration
8
On the [General] tab of the Parameter Configuration dialog box for the Master Unit, select
the [Edit Registration Table] check box.
When you select the [Registration Table] tab, the Slaves in the Network Configuration window
are displayed in the [Unregistered Device List].
9
Select the Slave you want to register from the [Unregistered Device List] and click the
Register [
] button.
The Slave Units will be registered and displayed in order of node address in the Registered
Device List.
10
To unregister a Slave, select the Slave you want to unregister from the [Registered
Device List], and click the Unregister [
] button.
Slave Units you unregister will be displayed again in the [Unregistered Device List].
11
Click the [Apply] button to save the Registration Table.
You return to the [General] tab.
12
On the [General] tab, click the [Transfer [PC to Unit]] button.
The settings are now transferred to the Master Unit.
13
At the end of the configuration steps, restart the network (cycle the power supply) and
check the MS and NS LED indicators on the Master Unit and on each Slave Unit to verify
that the network is established successfully.
If everything is correctly configured, both the MS (Module Status) LED and the NS (Network Sta-
tus) LED are lit green.
If the LED indicators indicate a different pattern, please refer to
page 6-1 to take corrective action.
Precautions for Correct Use
Precautions for Correct Use
• When downloading inverter parameters in the [Parameter Dialog] in CX-Integrator, always
check that the Remote I/O setting parameter P046 (Assembly Instance No.) is set correctly.
If a different parameter setting is transferred, the number of words occupied by the Com-
poNet Communications Unit will be changed, affecting the network configuration.
• For a third-party Master, configure the network according to the Master Unit's configuration
steps.
Содержание 3G3AX-MX2-CRT-E
Страница 58: ...2 CompoNet Communications Unit Mounting and Wiring 2 16 CompoNet Communications Unit User s Manual I582 E1...
Страница 94: ...3 Network Startup 3 36 CompoNet Communications Unit User s Manual I582 E1...
Страница 118: ...4 Remote I O 4 24 CompoNet Communications Unit User s Manual I582 E1...
Страница 134: ...5 Message Communications 5 16 CompoNet Communications Unit User s Manual I582 E1...
Страница 167: ...I 1 I CompoNet Communications Unit User s Manual I582 E1 Index...
Страница 171: ......