CMC 356 Reference Manual
86
6.10.7.2
Accuracy of Amplitude Measurement
The measurement values are given as effective values (rms).
The permitted input frequency range for the fundamental wave depends on
the specified sampling rate:
Table 6-44:
Sampling rate and input
frequency range
Valid for fundamental and harmonic waves in specified frequency range; accuracy
refers to full scale.
Table 6-45:
Sampling rate 28.44 kHz,
measurement range
600 V, 100 V, 10 V, 1 V
Table 6-46:
Sampling rate 28.44 kHz,
measurement range
100 mV
Table 6-47:
Sampling rate
9.48 kHz
3.16 kHz,
measurement range
600 V, 100 V, 10 V, 1 V
Sampling rate
Input frequency range
28.44 kHz
100 Hz (= fmin) ... 3200 Hz
9.48 kHz
30 Hz (= fmin) ... 1000 Hz
3.6 kHz
10 Hz (= fmin) ... 350 Hz
Frequency range
Accuracy
Typical
Guaranteed
fmin ... 1 kHz
± 0.1 %
± 0.3 %
fmin ... 10 kHz
+ 0.1 % / - 0.7 %
± 1.1 %
Frequency range
Accuracy
Typical
Guaranteed
fmin ... 1 kHz
± 0.2 %
± 0.5 %
fmin ... 10 kHz
+ 0.2 % / - 1.0 %
± 2.0 %
Frequency range
Accuracy
Typical
Guaranteed
fmin ... 100 Hz
± 0.1 %
± 0.3 %
fmin ... 1 kHz
+ 0.1 % / - 0.5 %
± 0.8 %
fmin ... 4 kHz
(sampling rate = 9.48 kHz)
+ 0.1 % / - 0.8 %
±1.2 %
fmin ... 1.4 kHz
(sampling rate = 3.16 kHz)
+ 0.1 % / - 0.8 %
±1.2 %
Содержание CMC 356
Страница 1: ...CMC 356 User Manual...
Страница 38: ...CMC 356 Reference Manual 38...
Страница 100: ...CMC 356 Reference Manual 100...
Страница 104: ...CMC 356 Reference Manual 104...
Страница 132: ...CMC 356 Reference Manual 132...
Страница 136: ...The OMICRON Bootloader Software Copyright Notices 136...
Страница 138: ...Contact Information Technical Support 138...