CMC 356 Reference Manual
110
CMIRIG-B timing specifications
Figure 9-7:
CMIRIG-B
timing in detail
Table 9-3:
Timing specifications
For ordering information about the
CMIRIG-B,
refer to table 9-5, "Order
numbers overview" on page 128.
For detailed information about the OMICRON
CMIRIG-B
interface box
please refer to the CMIRIG-B Reference Manual.
Detailed information about the IRIG-B standard can be found, for example,
in the IRIG SERIAL TIME CODE FORMATS publication at the url
https://wsmrc2vger.wsmr.army.mil/rcc/manuals/200-04/index.html
.
Detailed information about how to configure the
Test Universe
software
component
Time Trigger Configuration
for the use of
CMIRIG-B
with or
without
CMGPS
can be found in the
CMIRIG-B
Reference Manual and in the
Test Universe
Help, topics
Time Trigger Configuration
and
Hardware
Configuration
(
IRIG-B & GPS
tab).
CMC 356
analog
outputs
IRIG-B OUT
PPX OUT
CMGPS 1PPS,
IRIG-B/PPS IN
Timing specifications
T1 (delay time PPS source to PPX OUT) < 1µs typ., 1.5µs max.
T2 (time skew PPX OUT to IRIG-B OUT) < ± 0.1µs typ., ± 0.5µs max.
T3 (time error of time reference source to
analog outputs)
1
- Current outputs
- Voltage outputs
1
Valid for
CMC 356
output frequencies < 100Hz and re-synchronized analog output signals.
± 5µs typ., ± 20µs guar.
± 1µs typ., ± 5µs guar.
Содержание CMC 356
Страница 1: ...CMC 356 User Manual...
Страница 38: ...CMC 356 Reference Manual 38...
Страница 100: ...CMC 356 Reference Manual 100...
Страница 104: ...CMC 356 Reference Manual 104...
Страница 132: ...CMC 356 Reference Manual 132...
Страница 136: ...The OMICRON Bootloader Software Copyright Notices 136...
Страница 138: ...Contact Information Technical Support 138...