CMC 356 Reference Manual
72
6.10.5
Accuracy of Binary/Analog Inputs with Option ELT-1
The technical data for the binary inputs change with the installation of option
ELT-1.
Figure 6-20:
Simplified diagrams of
analog and binary inputs
with option ELT-1 installed
ANALOG DC INPUT
Only available with option ELT-1.
PTC
0 - ±20 mA
0 - ±10 V
BINARY/ANALOG INPUT
500k
Ω
500k
Ω
3 - 10 identical
Circuit diagram of a binary input
for potential-free operation
240 k
Ω
500k
Ω
25 pF
Vin +
Vin -
2.5V
12V
Vcomp
1 M
Ω