2FD/2FF/2FG-3.0
1-4-11
Section
Item
Maintenance item contents
Initial
No.
setting*
U093 Setting the exposure density gradient
• Text and photo/text/photo/text in fax mode/photo in fax mode
0/0/0/2/3
U099 Initializing original size
—
U100 Checking the operation of main high voltage
—
U101 Setting high voltages
• Developing bias AC component frequency at image formation
0
• Developing bias AC component duty at image formation
0
• Developing shift bias potential at image formation
0
• Transfer control voltage
120
U109 Displaying the drum type
—
U110 Checking/clearing the drum count
—
U112 Setting toner refresh operation
• Time of toner refreshment
120
• Developing bias on time
700 (30 cpm)
540 (40/50 cpm)
U113 Performing the drum refreshment
—
U114 Setting separation charger mode
• Specifying SC Whole mode to ON/OFF
ON
• Specifying the temperature/humidity of which SC Whole mode in ON
20/50
• Specifying SC Whole mode to ON/OFF when using thin paper
OFF
• Specifying SC Whole mode to ON/OFF when using plain paper
MODE0
U117 Checking the drum number
—
U118 Displaying the drum history
—
U130 Initial setting for the developer
—
U144 Setting toner loading operation
MODE2
U150 Checking sensors and switches for toner
—
U157 Checking/clearing the developing drive time
—
U158 Checking the developing count
—
U161 Setting the fixing control temperature
• Control temperature during copying
130
• Primary stabilization fixing temperature
115 (30 cpm)
120 (40/50 cpm)
• Secondary stabilization fixing temperature
130 (30 cpm)
145 (40/50 cpm)
• Time from power on to stabilization of fixing
0
• Fixing temperature decrease amount for duplex copying
5
• Fixing temperature decrease amount for duplex copying for copy store
0
section/optional mail box ejection
• Fixing correct temperature for large size copying
45 (30 cpm)
50 (40 cpm)
65 (50 cpm)
• Fixing correct temperature for middle size copying
45 (30 cpm)
60 (40 cpm)
70 (50 cpm)
• Fixing correct temperature for small size copying
25 (30 cpm)
40 (40 cpm)
45 (50 cpm)
• Fixing temperature increase amount at low temperature and low humidity
5
• Fixing temperature decrease amount at high temperature and high humidity
0
• Variable range of correct temperature for fixing heater M
0
U162 Stabilizing fixing forcibly
—
U163 Resetting the fixing problem data
—
U165 Checking fixing counts
—
U196 Turning the fixing heater on
—
U198 Setting the fixing phase control
OFF
U199 Checking the fixing temperature
—
* Initial setting for executing maintenance item U020
High voltage
Developing
Fixing and
cleaning
Optical
Содержание d-Copia 300
Страница 1: ...d Copia 300 d Copia 400 d Copia 500 SERVICE MANUAL Published in April 2005 842FG112 Version 3 0...
Страница 4: ...This page is intentionally left blank...
Страница 32: ...1 3 9 2FD 2FF 2FG 3 0 This page is intentionally left blank...
Страница 351: ......