2FD/2FF/2FG
1-5-29
Code
Contents
Remarks
Causes
Check procedures/corrective measures
C3200
C3300
C4000
C4010
C4200
Exposure lamp problem
• Non-lighting of the exposure lamp is
detected at the beginning of copying.
Optical system problem
• After AGC, correct input is not ob-
tained at CCD.
(This code is not displayed. The service
call counter counts the frequency of
occurrence only as for this code.)
Polygon motor synchronization
problem
• When the polygon motor starts, the
motor does not become stable even
after 20 s.
Polygon motor steady-state problem
• When high-speed rotation from low-
speed rotation is requested, the motor
does not become stable even after 20
s.
BD steady-state problem
• The VTC detects a BD error for 600
ms after the polygon motor rotation
has been stabilized.
Poor contact of
the connector ter-
minals.
Defective main
PCB.
Defective
exposure lamp.
Poor contact of
the connector ter-
minals.
Defective main
PCB.
Defective
exposure lamp.
Poor contact in
the polygon motor
connector termi-
nals.
Defective polygon
motor.
Defective power
source PCB.
Defective main
PCB.
Poor contact in
the polygon motor
connector termi-
nals.
Defective polygon
motor.
Defective power
source PCB.
Defective main
PCB.
Defective laser
diode.
Defective polygon
motor.
Defective main
PCB.
Check the connection of connector YC34
on the main PCB, and the continuity across
the connector terminals. Repair or replace
if necessary.
Replace the main PCB and check for cor-
rect operation.
Replace the exposure lamp or inverter
PCB and check for correct operation.
Check the connection of connector YC34
on the main PCB, and the continuity across
the connector terminals. Repair or replace
if necessary.
Replace the main PCB and check for cor-
rect operation.
Replace the exposure lamp or inverter
PCB and check for correct operation.
Reinsert the connector. Also check for con-
tinuity within the connector cable. If none,
remedy or replace the cable.
Replace the LSU (see page 1-6-20).
Check if 24 V DC is supplied to YC2-1 on
the main PCB. If not, replace the power
source PCB.
Check if 24 V DC is output from YC8-10 on
the main PCB. If not, replace the main
PCB.
Reinsert the connector. Also check for con-
tinuity within the connector cable. If none,
remedy or replace the cable.
Replace the LSU (see page 1-6-20).
Check if 24 V DC is supplied to YC2-1 on
the main PCB. If not, replace the power
source PCB.
Check if 24 V DC is output from YC8-10 on
the main PCB. If not, replace the main PCB.
Replace the LSU (see page 1-6-20).
Replace the LSU (see page 1-6-20).
Replace the main PCB and check for cor-
rect operation.