Maintenance
Description
item No.
2FD/2FF/2FG-3.0
1-4-40
U161
Setting the fixing control temperature
Description
Changes the fixing control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fixing problem on thick paper.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set and press the start key. The screen for executing each item is displayed.
Display
Description
CONTROL TEMP
Sets the fixing control temperature.
CORRECT TEMP
Sets the fixing correct temperature.
Setting the fixing control temperature
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display
Description
Setting range
Initial setting
CONT TEMP
Control temperature during copying
100 to 200 (°C) 130
1ST TEMP
Primary stabilization fixing
80 to 200 (°C)
115 (30 cpm)
temperature
120 (40/50 cpm)
2ND TEMP
Secondary stabilization fixing
100 to 200 (°C) 130 (30 cpm)
temperature
145 (40/50 cpm)
WARM UP TIM (S)
Time from power on to stabilization of fixing -5 to +20
0
DUP DOWN TEMP1 Fixing temperature decrease amount
0 to +20 (°C)
5
for duplex copying
DUP DOWN TEMP2 Fixing temperature decrease amount
0 to +20 (°C)
0
for duplex copying for copy store
section/optional mail box ejection
The respective temperatures are to be set such that 2ND TEMP >
= 1ST TEMP.
3. Press the start key. The value is set.
Setting the fixing correct temperature
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display
Description
Setting range
Initial setting
COPY UP TEMP(L)
Fixing correct temperature
-30 to +100 (°C) 45 (30 cpm)
for large size copying
50 (40 cpm)
65 (50 cpm)
COPY UP TEMP(M)
Fixing correct temperature
-30 to +100 (°C) 45 (30 cpm)
for middle size copying
60 (40 cpm)
70 (50 cpm)
COPY UP TEMP(S)
Fixing correct temperature
-30 to +100 (°C) 25 (30 cpm)
for small size copying
40 (40 cpm)
45 (50 cpm)
L/L UP TEMP
Fixing temperature increase amount
0 to +20 (°C)
5
at low temperature and low humidity
H/H DOWN TEMP
Fixing temperature decrease amount
0 to +20 (°C)
0
at high temperature and high humidity
MH OFF UP TEMP
Variable range of correct temperature
-10 to 10
0
for fixing heater M
If the fixing offset occurs by over heat of fixing temperature, decrease the value of MH OFF UP TEMP to
lower the temperature of fixing heater M.
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.