2FD/2FF/2FG
1-4-17
Maintenance
Description
item No.
U019
Displaying the ROM version
Description
Displays the part number of the ROM fitted to each PCB.
Purpose
To check the part number or to decide if the ROM version is new from the last digit of the number.
Method
Press the start key. The last eight digits of the part number indicating the ROM version are displayed.
Display
Description
MAIN
Main ROM IC
MMI
Operation ROM IC
LANGUAGE(Stand.)
Standard language ROM IC
LANGUAGE(Option)
Optional language ROM IC
MAIN BOOT
Boot of main ROM IC
MMI BOOT
Boot of operation ROM IC
PRINTER
Boot of printer board ROM IC
NETWORK SCANNER
Network scanner ROM IC
POWER SAVE
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U020
Initializing all data
Description
Initializes all the backup RAM on the main PCB to return to the original settings.
Purpose
Used when replacing the backup RAM on the main PCB.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data in the backup RAM is initialized, and the original settings for Inch specifications
are set.
When initialization is complete, the machine automatically returns to the same status as when the main
switch is turned on and the display language to the initial setting of English.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key. The screen for selecting
a maintenance item No. is displayed.
U021
Initializing counters and mode settings
Description
Initializes the setting data other than that for adjustments due to variations between respective machines, i.e.,
settings for counters, service call history and mode settings. As a result, initializes the backup RAM according
to the specifications depending on the destination selected in U252.
Purpose
Used to return the machine settings to the factory settings.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data other than that for adjustments due to variations between machines is
initialized based on the destination setting.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.