2FD/2FF/2FG
1-3-10
6. Pass the connector of the key counter
through the aperture in the key counter
retainer, and insert into the connector of the
copier.
7. Seat the projection of the key counter cover
retainer in the aperture in the middle right
cover.
8. Fit the key counter cover with the key counter
socket assembly inserted to the key counter
cover retainer on the copier using the screw.
9. Insert the key counter into the key counter
socket assembly.
10. Turn the main switch on and enter the
maintenance mode.
11. Run maintenance item U204 and select
“KEY-COUNTER.”
12. Exit the maintenance mode.
13. Check that the message requesting the key
counter to be inserted is displayed on the
touch panel when the key counter is pulled
out.
14. Check that the counter counts up as copies
are made.
Figure 1-3-13
Projection
Connector
Connector
Key conuter cover
Key counter cover retainer (66060022)
M4
×
30 screws
(B1304300)
Содержание d-Copia 300
Страница 1: ...d Copia 300 d Copia 400 d Copia 500 SERVICE MANUAL Published in April 2005 842FG112 Version 3 0...
Страница 4: ...This page is intentionally left blank...
Страница 32: ...1 3 9 2FD 2FF 2FG 3 0 This page is intentionally left blank...
Страница 351: ......