2FD/2FF/2FG
2-3-12
Connector
Pin No.
Signal
I/O
Voltage
Description
1
GND
-
-
Ground
2
CFM2 REM
O
CFM2 ON/OFF
A1
FSSOL2
O
0/24 V DC
FSSOL release signal
A2
FSSOL1
O
0/24 V DC
FSSOL acutuate signal
A3
24V
O
24 V DC
24 V DC supply for FSSOL
A4
GND
-
-
Ground
A5
FSSW
I
0/5 V DC
FSSW ON/OFF
A6
5V
O
5 V DC
5 V DC supply for FSSW
A7
GND
-
-
Ground
A8
-
-
-
Not used
A9
5V
-
-
5 V DC supply
A10
GND
-
-
Ground
A11
ESW
I
0/5 V DC
ESW ON/OFF
A12
5V
O
5 V DC
5 V DC supply for ESW
A13
CFM1 24V
O
0/24 V DC
CFM1 ON/OFF
A14
GND
-
-
Ground
A15
GND
-
-
Ground
A16
CCSW
I
0/5 V DC
CCSW ON/OFF
B1
PFCL-U
O
0/24 V DC
PFCL-U ON/OFF
B2
UP24V
O
24 V DC
24 V DC supply for PFCL-U
B3
LO24V
O
24 V DC
24 V DC supply for PFCL-L
B4
PFCL-L
O
0/24 V DC
PFCL-L ON/OFF
B5
24V
O
24 V DC
24 V DC supply for RCL
B6
RCL
O
0/24 V DC
RCL ON/OFF
B7
5V
O
5 V DC
5 V DC supply for HUMSENS
B8
HUMSENS
I
DC0Å`5V
HUMSENS detection voltage
B9
GND
-
-
Ground
B10
ETTH
I
0 to 5 V DC
ETTH detection voltage
B11
EM B-D
O
0/24 V DC (pulse)
EM coil energization pulse (_B)
B12
EM B
O
0/24 V DC (pulse)
EM coil energization pulse (B)
B13
EM A-D
O
0/24 V DC (pulse)
EM coil energization pulse (_A)
B14
EM A
O
0/24 V DC (pulse)
EM coil energization pulse (A)
1
24V
I
24 V DC
24 V DC supply for PSW
2
MAIN SW OFF REM
O
0/5 V DC
PSW ON/OFF
3
24V
O
24 V DC
24 V DC supply for total counter*
4
TC REM
O
0/5 V DC
Total counter* signal
7
GND
-
-
Ground
8
SET SIG
I
0/5 V DC
Key counter* connection signal
9
24V
O
24 V DC
24V DC supply for key counter*
10
K.COUNT REM
O
0/5 V DC
Key counter* count signal
1
OFM RET
O
0/5 V DC
OFM*RET signal
2
OFM CLK
O
0/5 V DC (pulse)
OFM*CLOCK signal
3
OFM CWB
O
0/5 V DC
OFM*CWB signal
4
OCM ENABLE
O
0/5 V DC
OCM*ENABLE signal
5
OCM RET
O
0/5 V DC
OCM*RET signal
6
OCM CLK
O
0/5 V DC (pulse)
OCM*CLOCK signal
7
OCM CWB
O
0/5 V DC
OCM*CWB signal
8
OCM VREF
O
0/5 V DC
OCM* current control voltage Vref
9
OCM M3
O
0/5 V DC
OCM* drive control signal M3
10
OCM M2
O
0/5 V DC
OCM* drive control signal M2
11
OCM M1
O
0/5 V DC
OCM* drive control signal M1
YC14
Connected
to the
cooling fan
motor 2.
YC16
Connected
to the
FSSOL,
FSSW,
CFM1,
CCSW,
PFCL-U,
PFCL-L,
RCL,
HUMSENS
and EM.
YC31
Connected
to the PSW,
total
counter*
and key
counter*.
YC32
Connected
to the DP*.
*: Optional