UNMOUNTING THE Z AXIS MOTOR
Before attempting any of the operations described in this Chapter, first power off the machine and disconnect it
from the electrical outlet.
1
.
Unmount the rear centre panel as described in the Chapter
”UNMOUNTING THE UPPER BODY AND
PANELS”
.
2.
Unscrew the two Allen screws (5 mm) fastening the motor mounting to the printer body. Disconnect the
motor quick connector.
Figure 4-60
3.
Undo the (1.5 mm) setscrew (
1
) and remove the gear mounted on the motor shaft. Unscrew the four (3
mm) hex screws (
2
) so as to separate the motor from its mounting (in the figure the two screws on the
connector side are shown).
Figure 4-61
4.
To reassemble follow the same procedures described above but in reverse order.
Hex Screws
Motor Fast Connector