190
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Monitoring the Network with SNMP
This trap is generated when a duplicate MAC address is detected on a port in a
TrCRF which already has learned that MAC address.
oc8600TsDuplicateBridge
This trap is generated when a duplicated bridge number is detected on a port in a
TrCRF.
oc8600TsRingNumberMismatch
This trap is generated when a mismatch in ring numbers is detected on a port in
TrCRF.
Traps for the Spanning Tree Protocol
oc8600TsTrCRFNewRoot
This trap is a TrCRF specific version of the newRoot trap as described in RFC1493.
The newRoot trap indicates that the sending agent has become the new root of the
spanning tree; the trap is sent by a bridge soon after its election as the new root, e.g.,
upon expiration of the Topology Change Timer immediately subsequent to its
election.
oc8600TsTrCRFTopologyChange
This trap is a TrCRF specific version of the topologyChange trap as described in
RFC1493.
A topologyChange trap is sent by a bridge when any of its configured ports
transitions from the Learning state to the Forwarding state, or from the Forwarding
state to the Blocking state. The trap is not sent if a newRoot trap is sent for the same
transition.
oc8600TsTrBRFNewRoot
This trap is a TrBRF specific version of the newRoot trap as described in RFC1493.
The newRoot trap indicates that the sending agent has become the new root of the
spanning tree; the trap is sent by a bridge soon after its election as the new root, e.g.,
upon expiration of the Topology Change Timer immediately subsequent to its
election.
oc8600TsTrBRFTopologyChange
This trap is a TrBRF specific version of the topologyChange trap as described in
RFC1493.
A topologyChange trap is sent by a bridge when any of its configured ports
transitions from the Learning state to the Forwarding state, or from the Forwarding
state to the Blocking state. The trap is not sent if a newRoot trap is sent for the same
transition.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......